Optional Drip Piping Arrangements - Hussmann Impact Excel M5X Installation And Service Manual

Medium temperature meat, delicatessen, dairy and produce merchandisers
Hide thumbs Also See for Impact Excel M5X:
Table of Contents

Advertisement

D
P
3-2
RIP
5. Provide a suitable air break between
flood rim of the floor drain and outlet of
drip pipe. To meet code on low base
merchandisers, it may be necessary
to install a field-supplied drip pipe
reducer. An alternative is to cut the
last section of drip pipe at an angle.
Always Slope Toward Floor Drain
Bottom of Case
One Water Seal per Run of Drip Pipe
P/N 0463880_E
S
IPING AND
PLASHGUARDS
It is the installing contractor's responsibility to consult
local agencies for local code requirements.
Bottom of Case
Slope
Optional Excel Drip Piping Arrangements
6. Prevent drip pipes from freezing:
a. Do NOT install drip pipes in contact with
uninsulated suction lines. Suction lines should
be insulated with a nonabsorbent insulation
material.
b. Where drip pipes are located in dead air
spaces, such as between merchandisers or
between a merchandiser and a store wall,
provide means to prevent freezing.
Slope
Bottom of Case
.
.
WWW
HUSSMANN
COM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Impact excel m5ep

Table of Contents