Data Interface X2; Transmission Protocol For Operating System Ljos - Leibinger Jet 2 Manual

Table of Contents

Advertisement

Group 5

5.3.2 Data interface X2

The operation of the LEIBINGER-JET 2 is normally done via the LCD touch display. The
RS 232 input on the rear side of the device (9-pole plug, female, interface X2) can be
used as an external data interface for connection to a PC, notebook or host. The
standard baud rate is 38400 Baud.
For older software versions the baud rate can be reduced to 9600 baud with the help of
a special bridge plug. Further more a special plug to increase the transmission rate to
115200 is obtainable on request.
The interface enables the downloading/running of software, of jobs and of graphic
symbols. A special connection cable and the Leibinger LJ-FLASH program is required to
use this function.
Further more this interface can be used via a PC for a comfortable programming of one
or more Leibinger-Jet 2. For this you would need additionally the Leibinger-software Win
Jet.

5.3.2.1 Transmission protocol for operating system LJOS

The programming device that is connected to the LEIBINGER-JET 2 must work with the
following transmission protocol:
! Asynchronous Mode
! 8 bit/character
Figure 6
Release 3.00
Transport/start up
When using a personal computer with RS 232 C interface a
maximum connection cable length of 10 metres should not be
exceeded, with greater transmission distances the use of an RS
422 connection is recommended.
! 1 stop bit
! Parity = no parity, no parity calculation
Page 34
Leibinger-Jet 2 se