Burners Technical Data Table (Itgb); Burners Technical Data Table - Lotus CF4-68GEM Installation And Operating Instructions Manual

Professional cooker with electric oven
Table of Contents

Advertisement

BURNERS TECHNICAL DATA TABLE (ITGB)

4 BURNERS TECHNICAL DATA TABLE (ITGB)
4.1

Burners technical data table

Technical data table - Burner CF S60GE
 
Burner max 3.5 KW-min 1.2kW
Burner injector 1/100 mm
Minimum adjustment 1/100 mm
Consumption
Primary air h = mm
Burner max 5.5 KW-min 1.8kW
Burner injector 1/100 mm
Minimum adjustment 1/100 mm
Consumption
Primary air h = mm
 
12.68 kWh/KG
G30
BUTANE
30 mbar
93
60
kg/h 0.273
27
117
70
kg/h 0.43
27
Translation of the original instructions
17
12.87 kWh/KG
G31
PROPANE
37 mbar
 
 
93
60
kg/h 0.273
27
 
 
117
70
kg/h 0.43
27
9.45 kWh/m3st.
G20
METHANE H
20 mbar
 
145
adjustable
m3 st./h 0,37
14
 
180
adjustable
m3 st./h 0.582
14