  • Page 1 PASTA COOKER FOR Instructions PROFESSIONAL USE for installation and use OPERATION & MAINTENANCE INSTRUCTIONS Mod. CP-94G CP-98G 563019000.doc Libr.istr.CP90G USA...
  • Page 2: For Your Safety

    1.48.1 a FOR YOUR SAFETY Do not store or use gasoline or other flammablevapors or liquids in the vicinity of this or anyother appliance. WARNING : Improper installation, adjustment,alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
  • Page 3 CP-94G, CP-98G Scarico acqua R 1GF Allacciamento acqua R 1/2GM Targhetta caratteristiche Attacco gas R 1/2GM Wasserabflussrohr R 1GF Wasseranscluß R 1/2GM Typenschild Gasanschluß R 1/2GM Evacuation d'eau R 1GF Raccord eau R 1/2GM Plaque des caractéristiques Raccord gaz R 1/2GM...
  • Page 4 FIG.B 9 10 11 562001001 12 15 17 16 Carico acqua Wasserzufuhr Remplissage d'eau Water filling Carga agua Cannette gas Gasschläuche Conduites gaz Gas pipes Bastoncillos gas By-pass By-pass By-pass By-pass By-pass Manopola Drehknopf Commande Knob Mando Cannette acqua Wasserschläuche Conduites eau Water pipes Bastoncillos agua...
  • Page 5 FIG.C Piezoelettrico Piezoelektrischer Anschluss Bypass Piézoélectrique Piezoelectric device Piezo eléctrico FIG.D 560094800M00P00 Bracket Staffa Bügel Bride Brida Iniettore Piloto Pilota Zündflamme Veilleuse Piloto Einspritzventil Thermocouple Termocoppia Thermoelement Thermocouple Termopar Injecteur Candela Bougie Ignition Candela Zündkerze Injector accensione d'allumage spark encendido Cable Cavo Kabel...
  • Page 6 FIG.E Rubinetto carico acqua Wasserzufuhr Hahn Robinet remplissage d’eau Water filling Tap Grifo carga agua FIG.F Bypass acqua Wasser bypass Bypass eau Water bypass Bypass agua Allacciamento acqua Wasseranscluß Raccord eau Water connection Enlace agua R 1/2GM R 1/2GM R 1/2GM R 1/2GM R 1/2GM Evacuation...
  • Page 7 INSTALLATION’S INSTRUCTIONS INDEX INSTALLATION’S MANUAL ............................8 UNPACKING..................................8 PRESSURE REGULATOR............................. 8 TECHNICAL GAS DATA TABLE ..........................9 INSTALLATION................................9 CHECKING FOR CORRECT VENTILATION AND COMBUSTION AIR ............9 PIPE FOR GAS CONNECTION ............................ 9 CHECKING HEAT OUTPUT ............................9 Connection for liquid gas (Propane HD-5).................9 Connection with natural gas .....................10 “BURNERS”...
  • Page 8: Installation's Manual

    Via Calmaor, 46 - Tel. (0438) 778020- 778468 S.r.l. Fax (0438) 778277 Home page http:// www.lotuscookers.it APPARECCHIATURE ELETTROGAS E-Mail: lotus@lotuscookers.it FAST FOOD •COTTURA • ASPIRAZIONE INSTALLATION’S MANUAL 1.48.1 d Keep the appliance area free and clear from combustibles. 1.48.1 e Not obstruct the flow of combustion and ventilation air, 1.48.1 f...
  • Page 9: Technical Gas Data Table

    TECHNICAL GAS DATA TABLE MODEL CP-94G CP-98G DIMENSIONS cm 40x90x90h 80x90x90h TOTAL NOMINAL POWER(BTU/h) 47,600 95,200 GAS CONNECTION R 1/2GM R 1/2GM WATER FILLING R 1/2GM R 1/2GM WATER DRAINAGE R 1GF R 1GF INSTALLATION 1.48.1 i, p The appliance must be installed in accordance with the ANS Z83.11a CSA 1.8a-(2001) Food Service Equipment, •...
  • Page 10: Connection With Natural Gas

    Orifices necessary for LP (propane) (natural) conversion are provided .* Check the plate, read the pressure and verify that the description of the nozzle installed corresponds to the one supplied by the manufacturer. “BURNERS” TECHNICAL DATA TABLE CP-94G Nominal Reduced Primary air...
  • Page 11 • Examine the flame of the pilot burner; it must lap the thermocouple and be blue, otherwise examine the nozzle of the pilot burner. • Check the lighting and flame of the main burner. • We urge the user to follow the instructions when using the appliance.
  • Page 12 OPERATOR’S AND MAINTENANCE INSTRUCTIONS INDEX WATER CONNECTION AND DRAINAGE....................... 13 INSTRUCTIONS FOR USE............................13 LIGHTING AND ADJUSTING THE BURNER......................13 TURNING OFF THE APPLIANCE..........................13 EMPTYING THE TUB..............................13 INSTRUCTIONS FOR DISCHARGING GAS EMISSIONS ..................14 Type “A” Appliances........................14 In the event of forced discharge ....................14 CLEANING AND MAINTENANCE..........................
  • Page 13: Water Connection And Drainage

    HECKING FUNCTIONING • The instructions necessary for use are enclosed with the appliance. • Check the appliances for gas leaks. • Examine the flame of the pilot burner; it must lap the thermocouple and be blue, otherwise examine the nozzle of the pilot burner.
  • Page 14: Instructions For Discharging Gas Emissions

    it is recommended to carry out this operation using water which is not too hot. INSTRUCTIONS FOR DISCHARGING GAS EMISSIONS Type “A” Appliances Type “A” appliances must discharge the products of combustion into extractor hoods or similar devices connected to and efficient chimney, or directly outside.