MODELS
CF4-78ET CFQ4-78ET
DIMENSIONS cm
80x70x90
400V 3N
POWER SUPPLY
MAXIMUM
27,8 A
ABSORPTION
MAXIMUM POWER
15,4 kW
POWER SUPPLY
5x4 mm²
CABLE
(Silicone)
POWER SUPPLY
MAXIMUM
ABSORPTION
MAXIMUM
POWER.
POWER SUPPLY
CABLE (Silicone)
The data plate is on the front (see diagram in electric connection item) and has all the data necessary for the connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessibile.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishings, etc. , these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules,when connecting the appliance,an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription, ECI norms.
The appliance is supplied without the connection cable. To install the power supply cable, proceed as follows:
Disconnect the power supply.
Remove the front panel
Push the connection cable through the cable blocker, connect the conductor wires to the corresponding terminals in
the junction box and fix them into place.
GB
IT

TECHNICAL DATA TABLE

CFC4-78ET CF6-712ETV CFQ6-712ETV CF6-712ET CFQ6-712ET
80x70x90
80x70x90
400V 3N
400V 3N
50Hz
50Hz
27,8 A
15,4 kW
5x4 mm²
5x4 mm²
TRANSFORMATION
INSTRUCTIONS FOR INSTALLATION

INSTALLATION

LAWS, TECHNICAL RULES AND NORMS

ELECTRIC CONNECTION

IE
CH
120x70x90
400V 3N
50Hz
50Hz
27 A
33 A
15 kW
20,6 kW
5x6 mm²
20
120x70x90
120x70x90
400V 3N
400V 3N
50Hz
50Hz
33 A
33 A
20,6 kW
22,5 kW
5x6 mm²
5x6 mm²
120x70x90
400V 3N 50Hz
33 A
22,5 kW
5x6 mm²

Advertisement