Echosounder Configuration

Echosounder Configuration
Parameter
[ECHOSOUNDER]
CABLE_LENGTH_M
MAX_DEPTH_M
MIN_DEPTH_M
Echologger ECT400 Configuration
Parameter
[ECHOLOGGER_ECT]
ALT_THRESHOLD_PCT
BAUD_RATE
DEADZONE_MM
FREQUENCY_HZ
GAIN_DB
MAX_SENSOR_ANGLE_DEG
Copyright © 2019—2022, SPH Engineering
Default
Description
Value
0
Echosounder cable length, m
20
Max depth value, m
0.5
Min depth value, m
Default
Description
Value
Altimeter threshold in percents of a full
10
scale
115200
UART baud rate, bps
Near field zone where detection is
300
ignored, mm
10
Measuring frequency, Hz
0
Amplifying gain, dB
Data filtering by tilt. The data are not
10
recorded if the sensor tilt value is
greater than the specified value, degree.
93
UgCS SkyHub User Manual
Table 6.14 — Common echosounder settings