Remote Water Sampling Setup
Remote Water Sampling Setup
Drop Messenger Setup
1. Set DROP_MESSENGER item to true in [PAYLOADS] section:
[PAYLOADS]
DROP_MESSENGER=true
2. DROP_MESSENGER plugin has only one purpose is to drop messenger to close Ruttner
water sampler. UgCS SkyHub drops the messenger using servo controlled through
PWM. By default, it's used the following PWM settings:
[DROP_MESSENGER]
SERVO_LOCK_PULSE_MS=1.5
SERVO_PERIOD_MS=10
SERVO_UNLOCK_PULSE_MS=0.5
See
Drop Messenger Configuration
Anemometer Setup
There are common anemometer settings in the [ANEMOMETER] section. Check whether
minimum and maximum values correspond to your needs:
[ANEMOMETER]
MIN_WIND_SPEED_MPS=0
MAX_WIND_SPEED_MPS=10
These values are used to bound valid wind speed values. When the wind speed is out of the
limits, the operator will be notified.
FT Technologies FT742-SM Setup
1. Set FTTECHNOLOGIES_FT742_SM item to true in [PAYLOADS] section:
[PAYLOADS]
FTTECHNOLOGIES_FT742_SM=true
See
FT Technologies FT742-SM Configuration
and descriptions.
Copyright © 2019—2022, SPH Engineering
to find details and descriptions.
to find all available settings with default values
56
UgCS SkyHub User Manual
Revision 6 • February 2022