Masonry Clearances - Valor 738BVN Installation And Owner's Manual

Natural gas / propane fuel, b vent gas insert
Table of Contents

Advertisement

6.1 Existing Fireplace (Masonry or Factory-Built)
The model 738 is intended for installation into masonry or listed factory-built fi replaces. Masonry fi replaces
must be built according to the requirements of the standards for chimneys, fi replaces, vents and solid-fuel
burning appliances, NFPA 211 (Latest Edition) or the applicable national, provincial, state or local codes. The
section 6.2 shows the minimum install dimensions for the model 738.
5"
f i r e - p a r t s . c o m
Distance from unit (engine) to combustible wall
Note: The model 738 is certifi ed without requiring a hearth projection,
although local codes may require a minimum hearth projection.

Masonry Clearances

5"
X
Y
Check that masonry step does not interfere with
install dimensions or vent pipe.
If mantel is combustible see section 6.2 for
allowable clearances.
Minimum width of fi replace opening at front =28"
X = 12-5/8" for Contoured Outer Trims
X = 12 " for Deluxe Outer Trims
Y = 20"
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

738bvp

Table of Contents