12.1.2 Cleaning Instructions

NOTE: Before they can be serviced, equipment exposed to biological, radioactive, or toxic materials must be cleaned and
disinfected. Biological contamination is presumed for any instrument, probe, or other device that has been used with body
fluids or tissues, microorganisms or with wastewater. Radioactive contamination is presumed for any instrument, probe or
other device that has been used near any radioactive source.
If an instrument, probe, or other part is returned or presented for service without a Cleaning Certificate, and if in our
opinion it represents a potential biological or radioactive hazard, our service personnel reserve the right to withhold
service until appropriate cleaning, decontamination, and certification have been completed. We will contact the sender for
instructions as to the disposition of the equipment. Disposition costs will be the responsibility of the sender.
When service is required, either at the user's facility or at YSI, the following steps must be taken to insure the safety of our
service personnel.
1. In a manner appropriate to each device, decontaminate all exposed surfaces, including any containers. See Section
8.1for a list of authorized cleaning agents. Instruments used with wastewater may be disinfected with 0.5% Lysol if
this is more convenient to the user. Autoclavable products may be autoclaved.
2. The user shall take normal precautions to prevent radioactive contamination and must use appropriate
decontamination procedures should exposure occur.
3. If exposure has occurred, the customer must certify that decontamination has been accomplished and that no
radioactivity is detectable by survey equipment.
4. Any product being returned to the YSI Repair Center should be packed securely to prevent damage.
5. Cleaning must be completed and certified on any product before returning it to YSI.
12.2

YSI Factory Authorized Service Centers

United States
YSI Incorporated
Repair Center
1725 Brannum Lane
Yellow Springs, OH 45387
Phone: 937 767-7241
Fax: 937 767-9353
Rochelle Scientific
1966 Tice Valley Blvd., #430
Walnut Creek, CA 94595
Phone: 877 527-8494
Fax: 707 307-7130
RJM Sales
454 Park Avenue
Scotch Plains, NJ 07076
Phone: 800 752-9055
Fax 908 322-2160
Giangarlo Scientific
162 Steuben St.
Pittsburgh, PA 15220
Phone: 412 922-8850
Fax: 412 922-9047
Scimetrics Inc.
19407 Park Row, Ste. 102
Houston, YX 77084
Phone: 281-565-0066
Fax: 281-565-1570
Europe
YSI Life Sciences
Xylem
Longfield Road
Tunbridge Wells
Kent TN2 3EY
UK
Phone: 44 1892 500400
Fax: 44 1892 543115
Asia
Smartec Scientific Corp.
7F-6, No.12, Lane 609
Sec 5, Chung-Hsing Road
San Chung
Taipei
Taiwan
Phone: 886 2 2999-5767
Fax: 886 2 2999-5759
Canada
Mandel Scientific
2 Admiral Place
Guelph, ON U1G 4N4
Canada
Phone: 888-883-3636
Fax: 519-763-2005
12-2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2776

Table of Contents