Field
Protocols
Name
Flexnet
HH/TRHH/
Meter
RR
2 Leak
Detection
Consecutive
Reads
Flexnet
HH/TRHH/
Meter
RR
2 Leak
Detection
Threshold
Flexnet
HH/TRHH/
Meter 2
RR
Reading
Resolution
Flexnet
HH/TRHH/
Meter 2
RR
Type
Flexnet
HH/TRHH/
Meter 2
RR
Units
Flexnet
HH/TRHH/
Number of
RR
Index Dials
Flexnet
HH/TRHH/
Programming
RR
Result
Flexnet
HH/TRHH/
Programming
RR
Unsuccessful
Reason
Flexnet
HH/TRHH/
Sample
RR
Rate
Flexnet
HH/TRHH/
Service
RR
Type
Flexnet
HH/TRHH/
Signal
RR
Noise Ratio
Flexnet
HH/TRHH/
Transmit
RR
Mode
Imp/Exp
Function
Export
The consecutive number of intervals
with an increase in consumption
before a leak is flagged on Port 2
of the transmitter. The interval is
defined by the sample rate. Works in
conjunction with the Leak Detection
Threshold. Expressed as 24, 36, 48,
or 72 hours.
Export
The number of units that need to
pass per interval to flag a leak on
Port 2 of the transmitter. Works in
conjunction with Leak Detection
Consecutive Reads. Expressed as
Disabled, 1 count, 2 counts, or 10
counts.
Export
The resolution programmed into the
transmitter for Port 2 expressed as a
power of 10.
Export
Remote mount, single switch;
or Direct mount, dual switch as
entered through the programmer for
Port 1 of the transmitter.
Export
The units of measurement
programmed into the transmitter for
Port 2. Expressed as Cubic Feet,
Cubic Meters, Liters, or Gallons.
Export
Number of significant index
dials to be read electronically as
programmed into the transmitter.
May be 2, 3, or 4 dials.
Export
Result of the programming attempt
on an endpoint. Possibilities include
Successful, Unsuccessful, NAK, and
Length Error.
Export
Reason for the program failure.
Possibilities include No RF
Response From Module or No
RF Response From Module2 (this
indicates that a response was
received but from the wrong meter
ID.)
Export
How often the transmitter reads
the register. Expressed in hours or
minutes.
Export
W for water, G for gas, E for electric.
Export
Signal strength of the transmitter to
the tower, expressed in dB.
Export
The mode the transmitter has
defaulted to after programming:
Normal, mPass, or Boost. May also
be a combination of these preceded
by a corresponding ratio.
Max
Width
15
15
10
30
16
10
50
35
15
1
15
15
Appendix B: Import and Export Field Names | 154
Notes
Need help?
Do you have a question about the sensus AutoRead and is the answer not in the manual?
Questions and answers
we are getting a serial comms unavailable error, how do we fix it
To fix the "Serial Comms Unavailable" error for the Xylem Sensus AutoRead, follow these steps:
1. Ensure the HHD stand is connected to the PC using the serial cable.
2. Make sure the stand has electrical power.
3. Open the AutoRead program.
4. Let AutoRead scan the available COM ports on the PC to identify the correct port for communication with the stand and HHD.
This process helps AutoRead recognize the connection and resolve the communication issue.