Field
Protocols
Name
Read
All
Time(Hours)
Read
All
Time(Minutes)
Read
All
Time(Seconds)
Read Type
All
Reading
All
Register
All
Text
Reverse
All
KWH
Consumption
Route
All
Name
Route
All
Sheet
Comment
Service
All
Location
Line1
ServiceLocationLine
All
2
Sequence
All
Number
State
All
Units of
All
Measurement
Units of
All
Measurement
(Numeric)
Units of
All
Measurement
(Text)
Voice
All
Phone
Warning
HH/TRHH/
RRVE/RR
Zip
All
Imp/Exp
Function
Export
Hour portion only of Time of reading
transaction expressed as two digit
hour.
Export
Minute portion only of Time of
reading transaction expressed
as two digit value of number of
minutes.
Export
Seconds portion only of Time of
reading transaction expressed
as two digit value of number of
seconds.
Export
Type Code of Reading. How meter
was actually read. See chart in note
number 7 for a list of Read Types.
Export
The current/new meter reading
collected by the reading device.
Imp/Exp
The programmable text field from a
Sensus AMR register. Contains zero
to twenty ASCII characters.
Export
Reverse kilowatt hour consumption
reported on the electric meter.
Export
Name of Route in AutoRead being
exported
Imp/Exp
Meter Location Notes.
Imp/Exp
Can be used to specify meter
location within property
Imp/Exp
Can be used to specify meter
location within property
Export
The sequence of the actual order a
meter was read or noted in the field.
Imp/Exp
Mailing Address State
Import
The units of measurement of the
meter reading.
Export
The units of measurement of the
meter reading, gallons, cubic feet...
See Note 8 for a list of numeric
value for each type of unit.
Export
The units of measurement of the
meter reading. See note 8 for a list
of the text units.
Imp/Exp
Voice Telephone Number
Imp/Exp
Warning to operator. Appears
on HHD and VXU displays
accompanied by an audible alarm.
Imp/Exp
Mailing Address Zip Code
Max
Width
2
2
2
1
15
20
8
30
40
40
40
10
2
16
2
16
10
50
9
Appendix B: Import and Export Field Names | 150
Notes
7
8
8
8
Need help?
Do you have a question about the sensus AutoRead and is the answer not in the manual?
Questions and answers
we are getting a serial comms unavailable error, how do we fix it
To fix the "Serial Comms Unavailable" error for the Xylem Sensus AutoRead, follow these steps:
1. Ensure the HHD stand is connected to the PC using the serial cable.
2. Make sure the stand has electrical power.
3. Open the AutoRead program.
4. Let AutoRead scan the available COM ports on the PC to identify the correct port for communication with the stand and HHD.
This process helps AutoRead recognize the connection and resolve the communication issue.
This answer is automatically generated