Technical specifications
Performance features and options
Designation
Charge points type 2, 32 A acc. to IEC 62196-1,2 and 61851-1
Connector lock type 2
Flap lock type 2
Charge current can be set from 6 ... 32 A
Monitoring for contactor malfunction
Residual current circuit breaker type B 30 mA
RFID acc. to
•
•
•
Counter EHZ version EDL incl. illuminated viewing window
Maximum charging capacity can be configured via OCPP
OCPP 1.6
LED status light, viewing radius 300°, colored status message per charge point
Selection of charging point via pushbutton
4G module with antenna
Ethernet interface instead of 4G module
Overvoltage protection/lightning protection mains DEHN, with telecommunica-
tion function, overvoltage class I-III
Double closing
Internal HAK with meter field
Use in public outdoor areas
Videoplay advertising in the display
Base plate with foundation anchor (option B00)
Fixed charging cables
Double terminal (option A00)
Last Gasp function
Backend pre-configuration (integration test required)
Ad hoc payment method using Giro-e
A list of order options can be found in section Options available for orders (Page 116) in the
appendix.
108
● Standard, O available as an option
ISO 14443A
ISO 14443B
ISO 18092 ECMA-340
SICHARGE
CC AC22
SICHARGE Operating instructions, ERK
Operating Instructions, 06/2021, A5E48571690-AC
12
2
●
●
●
●
●
●
●
●
●
●
●
●
O
O
●
O
●
●
O
O
O
O
O
O