Use
3.3

Donning Procedure

NOTICE
i
i
Donning the device incorrectly may cause delay when using
the oxygen self-rescuer in emergencies.
Be sure to perform the following steps in the described
sequence.
3.3.1
Opening the container
1. Pull the lever up with forefinger or
thumb as far as it will go until the
fixing straps loosen.
Remove the lid
2.
.
6
3.3.2
Pulling the oxygen self-rescuer out
1. Get hold of the red loop on the ex-
posed part and pull the oxygen
self-rescuer out of the housing
smoothly in one go; doing so will
automatically activate the starter
cartridge
and
the
breathing bag will fill with oxygen
after about 6 seconds. The loose
packaging will fall off or may be
removed.
CAUTION
!
The activated starter will become hot!
Do not touch, danger of burning!
NOTICE
i
i