Donning The Chemical Protective Suit; Observe During Operation - Dräger CPS 7900 Instructions For Use Manual

Hide thumbs Also See for CPS 7900:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21
4.3

Donning the chemical protective suit

NOTICE
i
i
Get a second person to assist you with donning the
suit.
1. Put on underwear (breathable and sweat-absorbent
occupational clothing, cotton gloves).
NOTICE
i
i
You are recommended to insert the trouser legs of the
underwear into the socks to prevent the trouser legs
from slipping.
2. Don the self-contained breathing apparatus and the full
facepiece and check their function
3. Don the safety helmet or mask/helmet combination
4. If the chemical protective suit is equipped with gas-tight
integrated gloves.
a. Without shoes, first step into the right trouser leg then
into the left trouser leg.
b. Don the safety boots.
5. If the chemical protective suit is equipped with gas-tight
integrated safety boots:
a. Without shoes, first step into the right trouser leg and
into the safety boot, then into the left trouser leg and the
safety boot.
6. To prevent the cotton gloves from slipping down, attach
them with insulating tape to your wrist.
7. Pull up the chemical protective suit up to your waist.
8. If the chemical protective suit is equipped with a ventilation
unit:
a. Connect the air supply on the inside of the chemical
1
protective suit
.
b. Close the integrated waist belt.
9. If the chemical protective suit is equipped with D-connect:
a. Close the integrated waist belt.
10. If the chemical protective suit is equipped with a crotch
strap:
a. Hook the crotch strap onto the waist belt of the self-
contained breathing apparatus. Pull the end of the
crotch strap to adjust it to the desired length.
11. Pull the hood over the head and insert your right arm into
the right sleeve and glove. Slide the backpack of the
chemical protective suit over the respiratory protective
device. Insert your left arm into the left sleeve and glove.
12. Connect the lung demand valve to the full facepiece
13. Get a second person to close the fastener system. Always
pull zipper tab in direction of zipper mechanism. Do not use
force!
14. Close the zipper flap.
1
Observe the corresponding Instructions for Use.
Dräger CPS 7900
1
.
1
.
1
.
4.4

Observe during operation

CAUTION
!
A build-up of heat in the chemical protective suit can
cause the wearer to collapse, therefore, if necessary,
wear a cooling vest or use a suitable cooling system.
Never start a mission alone!
Observe the operating time, limitations or specific national
regulations. The maximum operating time may also
depend on the used respiratory protective device and the
operating conditions.
If no compressed air hoses are connected in protection
suits with ventilation units, close the ports with a protective
cap to avoid contamination.
If you are working with refrigerated media of temperatures
below -40 °C (-40 °F), use suitable overgloves (e. g.
Cryo-Industrial® Gloves by Tempshield, Inc.).
If sight is obstructed by fogging or icing on the inside of the
visor: pull one hand out of the sleeve and wipe visor, e. g.
with a cleaning cloth. The cleaning cloth can be stored in
the inside pocket.
Leave the contaminated area immediately in case of
emergency. Wait to open the fastener system until you
reach a clean area.
Use