Technical Data; Order List - Dräger Oxyboks K 35 A Instructions For Use Manual

Table of Contents

Advertisement

8

Technical data

Temperature class in acc. with CEN 50014
max. surface temperature
Storage temperature
Lowest temperature for use
Nominal usage period
Usage period before/after durability testing
at 30 L/min minute volume
at 35 L/min minute volume
at 50 L/min minute volume
Volume of breathing bag
Inhalation/exhalation resistance
at 35 L/min sinusoidal flow
at 35 L/min sinusoidal flow
towards the end of the usage period
CO
content
2
in inhaled air
in inhaled air
towards the end of the usage period
Temperature of inhaled air
at the end of the usage period
Weight
unopened
during use
Dimensions (W x H x D)
Life time
1)
carried daily
stored in depot
1) Single shift operation max. 8 h a day, 5 working days a week;
during multi-shift operation the intervals are reduced accordingly.
Oxyboks K 35 A
9
Designation and description
300 °C
0 °C...+50 °C
Dräger Oxyboks K 35 A
0 °C
Belt
25 minutes
Bump protector with rivets
35/35 minutes
Goggles
25/25 minutes
Pictographs (in pairs only)
(SABS 1737)
15/15 minutes
>6 liters
Indicator window
Dräger transport package
5.5 mbar
Dräger Oxyboks KT 35 (training unit)
max. 10 mbar
Spare parts list on request.
less than 1 Vol%
max. 2.5 Vol%
max. 75 °C (dry air)
approx. 2.3 kg
approx. 1.4 kg
240 x 198 x 110 mm
5 years
10 years

Order list

Technical data
Order number
63 04 720
67 33 934
63 04 633
63 03 670
67 33 682/
67 33 910
67 33 647
63 04 511
63 04 606