Operation And Diagnostics; Maintenance And Care - Festo EXPT-95 Operating Instructions Manual

Parallel kinematic system
Table of Contents

Advertisement

Operation and diagnostics

7
Operation and diagnostics
CAUTION
Crushing of body parts and damage to the system.
Unintended activation can trigger unexpected movements.
• Before any conversion or maintenance work or inspections of the system, ensure that the system is
safely brought to a standstill and is locked to prevent restarting.
Detached parts could execute unexpected movements or fall down.
• Secure the parts to prevent unexpected movements or bring them to a secure end position.
NOTICE
Maintenance work may only be conducted by trained personnel with corresponding qualifications in
accordance with this description.
7.1

Maintenance and care

Lubricate ball joints
– Lubricate the ball joints every 2000 operating hours with lubricant LUB-KC1 (tube included).
Description of the extension è 8.1.5 Demounting a pair of rods.
Lubricate the toothed belt axis
– Lubricate the toothed belt axes as follows:
EXPT
Toothed belt axis
Maintenance work
Lubrication interval
Lubricant
Position of the lubrica-
tion points
Tab. 17: Lubrication of the toothed belt axes
26
-95/-120
EGC-80-...-TB-KF
Grease the bearing guide at the lubrication points 1
every 6000 operating hours
Grease: Lub-KC1 (Festo)
1
-95-P8/-120-P8
Festo — EXPT-95/120 — 2021-08d