Viessmann Vitoligno 300-C Installation And Service Instructions Manual page 86

18 to 48 kw pellet boiler
Table of Contents

Advertisement

Codes
Code 1
(cont.)
Coding in the delivered condition
Start without delay, Set system temp
D6:-20
Start of additional heat generator
without delay
Condition:
Actual system temperature < set
system temperature minus selec-
ted value (here: 20 K)
Parallel operation
D7:1
Only with additional heat genera-
tors with own boiler circuit pump:
Parallel operation of both heat
generators is possible.
Heating
Key:
OT Outside temperature
RT Room temperature
K
Kelvin (temperature differential)
Coding
Coding in the delivered condition
Remote control
A0:0
Available if a remote control unit is
connected.
Without remote control
Summer eco function room temperature
A5:5
With heating circuit pump logic
function (economy mode):
Heating circuit pump "OFF" when
the outside temperature (OT) is 1
K higher than the set room temper-
ature (RT
Parameter ad-
Heating circuit pump "Off"
dress "A5":
Summer eco function active
1
OT
2
OT
3
OT
4
OT
5
OT
6
OT
7
OT
to
to
15
OT
86
)
set
RT
+ 5 K
>
set
RT
+ 4 K
>
set
RT
+ 3 K
>
set
RT
+ 2 K
>
set
RT
+ 1 K
>
set
RT
>
set
RT
1 K
>
set
RT
9 K
>
set
Possible change
D6:-100
Adjustable value in K
to
D6:0
D7:0
Parallel operation of both boilers is
not possible.
Possible change
A0:1
With Vitotrol 200-A.
Recognised automatically.
A0:2
With Vitotrol 300-A.
Recognised automatically.
A0:3
With Vitotrol 350.
Recognised automatically.
A5:0
Without heating circuit pump logic
function
A5:1
With heating circuit pump logic func-
to
tion
A5:15
See the following table: