Commissioning, inspection, maintenance
Commissioning the heating system
Selecting the type of changeover unit
Available if charging scheme "With changeover unit"
was previously selected.
Press the following buttons:
1.
/
"0" for "Changeover unit with backwash
|
~
function (4-way or 8-way)"
or
"1" for "Changeover unit with bypass func-
tion (wall mounted)"
or
"2" for "Revolver changeover unit with three
suction wands (fixed)"
Selecting the changeover unit/number of wands
Available if the changeover unit with backwashing type
"0" was previously selected.
Press the following keys:
1.
/
Number of wands of the changeover unit:
|
~
"2", "3", "4", "5", "6", "7" or "8".
Selecting the pellet store sensor
To specify whether a level sensor is present in the pel-
let store, press the following keys:
1.
/
for pellet store sensor "Yes/No"
|
~
Selecting external digital input
Available if "No" was selected for the cascade.
Press the following buttons:
1.
/
for external demand with external digital
|
~
input "No/demand/block".
Selecting external analogue input
Available if "No" was selected for the cascade.
Press the following buttons:
1.
/
for external default output with external ana-
|
~
logue input "Yes/No".
54
(cont.)
2.
to confirm.
d
2.
d
to confirm.
2.
To confirm.
d
2.
to confirm.
d
2.
to confirm.