Starting The Heating System - Viessmann Vitoligno 300-C Installation And Service Instructions Manual

18 to 48 kw pellet boiler
Table of Contents

Advertisement

Setting the heating curves
Reduced room temperature
110
A
C
B -20°C
D
Fig. 44
Changing the reduced room temperature
from 3 to 14 °C
Flow temperature in °C
A
Outside temperature in °C
B
Set room temperature in °C
C
D
Heating circuit pump OFF
Heating circuit pump ON
E
Changing the slope and level
The heating curve can be adjusted separately for each
heating circuit.
110
3.5
A
+20
Outside temperature in °C
Fig. 45
A
Changing the slope.
Changing the level (vertical parallel offset of the
B
heating curve).

Starting the heating system

Switch the heating system on by pressing the "START/
STOP" button on the boiler.
(cont.)
14°C
3°C
E
1.4
B
0.2
-20
Commissioning, inspection, maintenance
Press the following buttons:
1.
.
å
2.
/
for selecting the heating circuit.
|
~
3.
to confirm.
d
4.
/
for "Reduced room temperature".
|
~
5.
to confirm.
d
6.
/
for the required value.
|
~
7.
to confirm.
d
Press the following buttons:
1.
.
å
2.
/
for selecting the heating circuit.
|
~
3.
to confirm.
d
4.
/
for "Heating curve".
|
~
5.
to confirm.
d
6.
/
for "Slope" or "Level".
|
~
7.
to confirm.
d
8.
/
for the required value.
|
~
9.
to confirm.
d
10.
repeatedly until the default display
ä
is shown.
Note
If the pellet hopper has not been filled as far as the
sensor before switching on, the vacuum module will be
activated.