Viessmann Vitoligno 300-C Installation And Service Instructions Manual page 80

18 to 48 kw pellet boiler
Table of Contents

Advertisement

Codes
Code 1
(cont.)
Coding in the delivered condition
Charging scheme
Charging
Automatic charging with vacuum
scheme:1
module for vacuum supply system
from a pellet silo and for discharge
with manual changeover unit from
a pellet storage room.
DHW
DHW:No
No DHW heating installed
DHW circulation
DHW circula-
No DHW circulation is connected
tion:No
to the boiler control unit.
Fuel store sensor
Fuel store sen-
No level sensor installed in the fuel
sor:No
store.
Heating circuit 1
Heating circuit
No heating circuit 1 installed
1:No
Heating circuit 2
Heating circuit
No heating circuit 2 installed
2:No
Only available if at least one heat-
ing circuit was selected.
Heating circuit 3
Heating circuit
No heating circuit 3 installed
3:No
Only available if at least 2 heating
circuits were selected.
80
Possible change
Charging
No automatic charging of the boiler
scheme:0
Only for boilers
Charging
Automatic charging with vacuum
scheme:2
module and discharge screw con-
veyor.
Charging
Vacuum module with external charg-
scheme:3
ing
Charging
Vacuum module with changeover
scheme:4
unit.
2 to 8 suction wands selectable.
Charging
Discharge screw conveyor
scheme:5
Only for boiler
Charging
External charging
scheme:6
Only for boiler
Charging
Screw conveyor and discharge
scheme:7
screw conveyor
Only for boiler
Charging
Screw conveyor and external charg-
scheme:8
ing.
Only for boiler
DHW:On the boil-
DHW heating is connected to the
er
boiler control unit.
DHW:On the mix-
DHW heating is connected to the ex-
er module
tension kit.
DHW circula-
DHW circulation is connected to the
tion:Yes
boiler control unit.
Fuel store sen-
Level sensor installed in the fuel
sor:Yes
store.
Heating circuit
Heating circuit is connected to the
1:On the boiler
boiler control unit.
Heating circuit
Heating circuit is connected to the
1:On the mixer
extension kit.
module
Heating circuit
Heating circuit is connected to the
2:On the boiler
boiler control unit.
Heating circuit
Heating circuit is connected to the
2:On the mixer
extension kit.
module
Heating circuit
Heating circuit is connected to the
3:On the boiler
boiler control unit.
Heating circuit
Heating circuit is connected to the
3:On the mixer
extension kit.
module
48 kW.
18 kW.
18 kW.
18 kW.
18 kW.