EXPERT PN110
12.3.3. Water Consumption Daily
History
The controller has a 60-day water consump-
tion history menu. It can also show you the
amount of water consummed in the last &
previous 24 hours (see picture below).
Water Consumption
Previous 24h
Last 24h
• Water Consumption History:
1. Select:
» WATER
» 1. Water History
Water Consumption
20XX/01/01
0Gal
2. Press the down-arrow key once to look
at the total amount of water consumed since
the beginning of the batch.
3. Keep pressing on the down-arrow key to
scroll down the water consumption history.
• Water Consumption, Previous (P) and
Last (L) 24 Hours:
1. Select:
» WATER
» 2. Last 48Hr
Water Consumption
L.24Hr
0Gal
P.24Hr
0Gal
• Water Consumption, Previous (P) and
Last (L) 24 Hours per Head:
1. Select:
» WATER
» 3. Last 48Hr/Hd
Water Consumption
L.24Hr/Hd
0.000Gal
P.24Hr/Hd
0.000Gal

12.3.4. Other Daily History Menus

History menus give a daily record of probe
readings and of the animal count. These
pieces of information are logged into history
menus at midnight. Refer to section 11.3.1 to
consult run time histories (for heaters, water
consumption and feeders).
1. Select the desired history menu:
» AMBIENT TEMPERATURE
Time
» PROBE TEMPERATURES
Now
» OUTSIDE TEMPERATURE
» RELATIVE HUMIDITY
» STATIC PRESSURE
Ambient temperature — This menu contains
the daily minimum and maximum readings of
the room temperature of the past 7days.
Probe temperatures — This menu contains
the daily minimum and maximum temperature
readings of each temperature probe for the
past 7 days.
Outside temperature — This menu contains
the daily minimum and maximum readings
of outside temperature probes for the past
7 days. *This parameter is accessible if an outside
temperature sensor is enabled (section 4.7.1).
Relative humidity (RH) — This menu contains
the daily minimum and maximum inside
humidity readings of the past 7 days. * This
parameter is accessible if the inside humidity sensors
is enabled (sec. 4.7.1).
Static Pressure — This menu contains the
daily minimum and maximum static pressure
readings of the past 7 days. *This parameter
is accessible if a static pressure sensor is enabled
(sec. 4.7.1).

12.3.5. Resetting the Daily Histories

The controller automatically resets all his-
tories when the animal age goes from OFF
to 1 day.
1. Select:
» AGE & MORTALITY
2. Decrease the animal age until the word
"Off" is displayed. Press the Edit key again
to validate.
3. Now, set the animal age to 1 day. All
histories will be cleared afterwards (except
for the Alarm Log).

12.4. Hourly History Log

The controller has an history where the hourly
reading of each output is logged for the past
7 days.
The complete history log (190-day
history) can also be saved on a USB drive
and consulted on a computer. Refer to
the transfer menu in chapter 14 to save
the log on a USB drive.
1. Select:
» MONITORING
2. Select the desired history menu:
» 1. Temperature probes
» 2. Rel. humidity
» 3. Water meters
» 4. Feeders
» 5. Heaters
» 6. Set points
Temperature probes — This menu shows
the temperature probe readings that were
measured every hour for the past 7 days. It
also gives the hourly reading of the average
temperature.
Rel. humidity — This menu shows the relative
humidity levels that were measured every
hour for the past 7 days. * This history is ac-
cessible if the inside humidity sensors is enabled
(sec. 4.6.1).
EXPERT PN110 rev.23
37