EXPERT PN110
4.6.4.2.
Fan Stage Relays
1. Select:
» RELAY SETTINGS*
» 2. Fan Stages
» Select the desired fan stage
*A password is required to access this menu (sec.
4.2).
Stage 1 Relays:
Variable 1
On(1)
Variable 2
Var(1)
Relay 1
On (1)
Relay 2
Off(1)
Relay 3
Timer(1)
...
Relay 13
Off
(1)
Relay 14
Off
(1)
On Time
15sec
Off Time
0sec
2. Put a check mark to identify the relay(s)
used in the selected fan stage.
Variable Output Status — 2 variable outputs
can be used to provide variable-speed ventila-
tion. If they are used, assign each of them to
proper fan stages.
Var — The variable fan output is assigned
to the fan stage and operates in variable
mode: when the stage starts, the variable
fan starts running at its minimum intensity.
The fan intensity gradually increases as the
room temperature increases.
On — The variable fan output is assigned
to the fan stage and operates in on/off
mode: the fan runs at 100% when the fan
stage is on and stops when the stage is off.
Off — The variable output is not assigned.
If the last fan stage uses a variable output,
the output must use the on/off operating
mode. Do not set the operating mode of
the last fan stage to the variable mode.
Relay Status — Put a check mark to assign
a relay to the output or select "Timer" if load
connected to the relay must run in timer
mode.
Timer — If timer-based relays are assigned
to some fan stages set the "On Time" and the
"Off Time" of the timer.
4.6.4.3.
Natural Curtain Relays
Relays 7-8 and relays 13-14 have specially
been designed to connect actuators. When
actuators are connected to these relays, their
open and close relays can never be activated
at the same time.
1. Select:
» RELAY SETTINGS*
» 3. Curtain**
» x. Curtain x Open
or
» x. Curtain x Close
*A password is required to access this menu (sec.
4.2).
**This menu is accessible if the natural curtain is
enabled (sec. 4.5).
Curtain Open Relay
0
1
12345678901234

2. Put a check mark to identify the relay used
to open or to close the curtain.
4.6.4.4.
Inlet Relays
Relays 7-8 and relays 13-14 have specially
been designed to connect actuators. When
actuators are connected to these relays, their
open and close relays can never be activated
at the same time.
1. Select:
» RELAY SETTINGS*
» 4. Inlet**
» 1. Inlet Open
or
» 2. Inlet Close
*A password is required to access this menu (sec.
4.2).
* This menu is accessible if the inlet is enabled
(sec. 4.5).
Inlet Open Relay
0
1
12345678901234

2. Put a check mark to identify the relay used
to open or to close the air inlet.
4.6.4.5.
Stir Fan Relays
1. Select:
» RELAY SETTINGS*
» 5. Stir Fan**
*A password is required to access this menu (sec. 4.2).
**This menu is accessible if the stir fan output is
enabled (sec. 4.5).
Stir Fan Relays
0
1
12345678901234

2. Put a check mark to identify the relay(s)
used by the stir fan.
4.6.4.6.
Cooling Output Relays
It is possible to assign the same relays to
the cooling and soaking outputs. In this
case, the relays switch whenever one of
the two outputs is activated.
1. Select:
» RELAY SETTINGS*
» 6. Cooling**
*A password is required to access this menu (sec.
4.2).
**This menu is accessible if the cooling output is
enabled (sec. 4.5).
Cooling Relays
0
1
12345678901234

2. Put a check mark to identify the relay(s)
used by the cooling output.
EXPERT PN110 rev.23