0-10V Output Connection; User Interface; Location Of The Controls; How To Select & Modify The Parameters - Airstream EXPERT PN110 User Manual

Table of Contents

Advertisement

EXPERT PN110
should not be under 18 AWG) to ensure the
cable entry is liquid tight. Do not ground the
shielding.
It is preferable to solder the cable joint to
ensure a proper contact between the two
cables.
Do not run sensor cables next to other
power cables. When crossing over other
cables, cross at 90°.
Defective sensors: An alarm is generated
when a defective sensor is detected. Defec-
tive sensors are identifi ed in the "Alarm"
menu. Refer to chapter 10 for fur ther
information on the alarms.

2.2.4. 0-10V Output Connection

It is recommended to use a 18 to 22 AWG
wire to connect the devices to the 0-10V
outputs. This type of output can be used to
connect various devices such as lights.
Menu select
Main Menu
buttons
6
EXPERT PN110 rev.23

3. USER INTERFACE

3.1.

Location of the Controls

LCD Display — The LCD display gives the
current readings and displays the param-
eters when you select a function. When the
parameters for a given function cannot all be
presented at once on the display, arrows are
displayed on the right handside to indicate
that additional parameters can be displayed
using the arrow keys. After 15 minutes of
inactivity, the display returns to the AMBIENT
TEMPERATURE display.
LED Display — This screen shows the current
reading of chosen sensor(s). Refer to section
4.5 to select what information needs to be
shown on the LED display.
Menu Select buttons — The up and down-
arrow keys are used to scroll within the
main menu located on the left side of the
controller.
Arrow Keys — The up and down-arrow keys
are used to scroll within a function menu.
The right-arrow key is used to select a menu
option; the left-arrow key is used to go back
to the previous menu display.
Edit Button —ress this key to access a menu
on screen or to enter the editing mode (refer
to section 3.2 for further information about
this mode).
LCD Screen
Arrow keys
Outputt
LED Display

Status LEDs

3.2.
How to Select & Modi-
fy the Parameters
1. Use the arrow keys to select the desired
parameter. If the parameter is fl ashing on
screen means the parameter can be modi-
fi ed.
2. Press the "Edit" button to access the
editing mode. The parameter starts fl ashing
faster.
3. Use the up and down-arrow keys to
change the value of the parameter.
4. Press the "Edit" button once again to
validate the new value and to exit the edit-
ing mode.
3.3.
Status LEDs
LED
MEANING
CLEAN MODE
Turns on when the controller
operates in clean mode
ALARM
Turns on when an alarm is
active.
Flashes when an alarm
condition occurred and was
re-established by itself.
COOLING
Solid LED: Time ON of the
cooling timer.
Flashing LED: Time OFF of
the cooling timer.
SOAKING
Solid LED: Time ON of the
soaking timer.
Flashing LED: Time OFF of
the soaking timer.
STIR FAN
Turns on when the stir fan
output is ON
DE-ICING /
Turns on when a curtain is
PURGE
operaing in de-icing/purge
mode
CLOCK OUTPUT
Turns on when clock output
1-2
1-2 is active
0-10V OUTPUT
Turns on when 0-10V output
1-2
1-2 is active
CUR-
OPEN
Turns on when curtain 1-2 is
TAIN
opening
1-2
CLOSE
Turns on when curtain 1-2
is closing
INLET
OPEN
Turns on when the inlet is
opening
CLOSE
Turns on when the inlet
closing
FAN STAGE 1-8
Turns on when fan stage 1-8
is ON
HEATERS 1-3
Turns on when heater 1-3
is ON

Advertisement