Table of Contents

Advertisement

EXPERT PN110

9. CLOCK OUTPUTS

The controller has 2 outputs to control various
devices using the real-time clock. These clock
output can use up to 24 timer cycles. Refer to
the Installation setup in section 4.5 to enable
the desired number of cycles.
A clock output starts when the "On Time" of a
timer is reached; it either stops after a certain
run time or at a certain time of day. The fol-
lowing diagrams show both possibilities:
Time Clock:
Output
Start/Stop Mode
Status
Cycle
On
Off
Start Time
Stop Time
(e.g. 8h30AM)
(e.g. 9h00AM)
Time Clock:
Output
Status
Start/Run Mode
Cycle
On
Off
Run Time
(e.g. 30m:15s)
Start Time
(e.g. 8h30AM)
32
EXPERT PN110 rev.23
1. Select:
» START / STOP TEMPS
8. Clock outputs
»
Clock 1 Mode S/Stop
On 1
13:50 (1)
[or]
Run Time Hour
Min
0 Sec
Off 1
14:30 (1)
2. Set the following parameters:
Clock mode — The clock mode allows stop-
ping a clock output at a certain time of the
day or after a certain run time. Select "Start/
Stop" to specify the time at which each cycle
starts and stops or select "Start/Run" to
specify the running time of each cycle. Note
that the "Start/Run" option allows stopping
cycles with more precision since this mode
allows adjusting the seconds.
On Time / Off Time or Run Time — Set the
Time
time at which each cycle starts then set the
moment at which each cycle ends.
Time
0
0

Advertisement