6.3.6. Static Pressure Set Points

When the high pressure set point is reached,
the inlet opens to the static pressure compen-
sation value; it closes by the same amount
when the low pressure level is reached. The
static pressure high and low set points can
be adjusted from 0 to 0.2 inches of water.
1. Select:
» INLET
3. Stat pressure*
»
* This menu is accessible if the inlet is enabled
and if the static pressure sensor is used (sec. 4.5
and 4.7.1).
SP Set points
Low SP
.000"WC
High SP
.100"WC
2. Set the following parameters:
Low / High Set Points — Set the low and high
static pressure set points to the desired value.
EXPERT PN110 rev.23
23