EXPERT PN110
4.6.4.7.
Soaking Output Relays
It is possible to assign the same relays to
the cooling and soaking outputs. In this
case, the relays switch whenever one of
the two outputs is activated.
1. Select:
» RELAY SETTINGS*
» 7. Soaking**
*A password is required to access this menu (sec. 4.2).
**This menu is accessible if the soaking output is
enabled (sec. 4.5).
Soaking Relays
0
1
12345678901234

2. Put a check mark to identify the relay(s)
used by the soaking output.
4.6.4.8.
Clock Output Relays
1. Select:
» RELAY SETTINGS*
» 8. Clock Output**
» x. Select desired clock
*A password is required to access this menu (sec.
4.2).
**This menu is accessible if a clock output is enabled
(sec. 4.5).
Clock 1 Relays
0
1
123456789012345678

2. Put a check mark to identify the relay(s)
used by the soaking output.
12
EXPERT PN110 rev.23
4.6.4.9.
Output Deactivation in
Natural Vent.
The user can choose to deactivate some fan
outputs (On/Off or variable outputs) when
the curtain is suffi ciently opened while be-
ing in natural ventilation. Refer to section
6.4.5 for further information on the output
deactivation.
1. Select:
» RELAY SETTINGS*
» 9. Output Shutoff**
*A password is required to access this menu (sec.
4.2).
Nat. Vent.ShutOff
Variable 1?
Yes
Variable 2?
No
Natural Vent.Shutoff
0
1
12345678901234
2. Select the relays and/or variable outputs
that has to stop when the controller enters
in natural ventilation.
4.6.4.10. Backup Relay Box
Assign a relay to the backup relay box. This
normally closed relay opens when a controller
or power failure occurs.
1. Select:
» RELAY SETTINGS*
» 10. Backup**
*A password is required to access this menu (sec.
4.2).
Backup Relays
0
1
12345678901234

2. Put a check mark to identify the relay used
by the backup box.
4.6.4.11. Brooder Heater Relay
1. Select:
» RELAY SETTINGS*
» 11. Brooder**
» Select the desired brooder (regular or
Hi-Fire brooder)
*A password is required to access this menu (sec. 4.2).
**This menu is accessible if a brooder heater that
uses the relay mode is enabled (sec. 4.5).
Brooder Heater
0
1
12345678901234

2. Put a check mark to identify the relay(s)
used by the brooder heater.