6.2.1.3.
Outside Temperature
Compensation
Stage 1 and 2 bandwidths can be adjusted
automatically as a function of outdoor tem-
perature compensation.
temperature decreases, stages 1 and 2 band-
widths increase gradually to compensate for
the change. The user specifi es the bandwidth
used in summer as well as the bandwidth used
in winter for both variable outputs of stages
1 and 2. The bandwidths can be adjusted
from 1 to 10°F (0.6 to 5.6°C). The winter's
bandwidth must be even or greater than the
summer's bandwidth.
Bandwidth as a
Bandwidths
of stages
Function of
1 & 2
Outside Temperature
Winter
Bandwidth
Summer
Bandwidth
Winter
Note that the ventilation stages' start
temperatures will be adjusted following
the bandwidth fl uctuations as the outside
temperature changes.
18
EXPERT PN110 rev.23

6.2.2. Settings

6.2.2.1.
As the outside
1. Select:
» START / STOP TEMPS
»
Ventilation
Stage 1 On
Var1 bandwidth
Var2 bandwidth
2. Set the following parameters:
(Refer to the previous section to get further informa-
tion on these parameters)
On & Off Temperatures — Set the start and
stop temperatures of each fan stage.
Notes: Stage 1 stops when the room
temperature falls 0.3 °F below its start
temperature.
Outside
Summer
The minimum difference between two
consecutive start temperatures is of
0.5 °F (0.3 °C).
The start temperature of a fan stage
must be greater value than its stop
temperature.
Var1 & Var2 bandwidth — Set the number of
degrees required for variable fans to reach their
full speed in stages 1 and 2. If the "Outside
temperature compensation" function is used, set
these bandwidths separately for winter and for
summer (see sec. 4.5).
Start/Stop Temperatures
Note that the start temperature of a fan
stage is likely to change if the set point
changes or if the bandwidth changes
according to the outside temperature.
2. Fan Stages
70.0
2.0
2.0
6.2.2.2.
Season Change
If the outside temperature compensation on
the bandwidths of stages 1 and 2 is used, you
must specify at what outdoor temperature
winter and summer start.
1. Select:
» START / STOP TEMPS
» 10. Outdoor Comp.*
*This menu is accessible if the outside compensation
on stages 1-2 is enabled (sec. 4.5).
Outdoor Compensation
Summer Temp.
60.0
Winter Temp.
50.0
2. Set the following parameters:
Summer Temp. — Set the outside tempera-
ture at and above which summer bandwidths
must be used.
Winter Temp. — Set the outside tempera-
ture below which winter bandwidths must
be used.