Monitoring Functions; Current Conditions; Current Set Point; Daily Histories - Airstream EXPERT PN110 User Manual

Table of Contents

Advertisement

EXPERT PN110
12. MONITORING FUNC-
TIONS

12.1. Current Conditions

The following menus give a quick view of the
actual conditions in the barn as described
below:
Ambient Temperature — Select the AMBIENT
TEMPERATURE menu with the menu selec-
tors. The average room temperature of the
activated probe is displayed.
Ambient Temperature
Average:
76.9 °F
Cur.SetP:
70.0 °F
Pb1
On
Pb2
On
Probe Temperature — Select the PROBE TEM-
PERATURE menu with the menu selectors.
The current readings of each temperature
probe is displayed.
Probe Temperatures
Pb1 75.4
Pb2
78.1
Pb3 75.4
Pb4
78.4
Pb5 75.5
Pb6
78.6
Outside Temperature — Select the OUTSIDE
TEMPERATURE menu with the menu sectors.
The current outside temperature is displayed.
*Accessible if the outside temp. probe is enabled
(sec. 4.7.1).
Outside Temperature
Read Out:
72.3 °F
Today's Min / Max
Min
71.3 Max
74.2
Relative Humidity — Select the RELATIVE
HUMIDITY menu with the menu sectors.
The current humidity level in the room is
displayed. *Accessible if the humidity probe is
enabled (sec. 4.7.1).
Relative humidity
Read Out:
85%
Today's Min / Max
Min
60 Max
80
36
EXPERT PN110 rev.23
Static Pressure — Select the STATIC PRES-
SURE menu with the menu sectors. The cur-
rent static pressure is displayed. *Accessible
if the static pressure sensor is enabled (sec. 4.7.1).
Static Pressure
Read Out:
.193"WC
Today's Min / Max
Min
.190 Max .196
Time & Date — Select the TIME & DATE menu
with the menu sectors. The actual time and
date are displayed.
Time & Date
Y /M /D
Date
2001/03/29
Time
11:21:15
Animal Age & Count — Set the function to
AGE & MORTALITY using the menu select
buttons and then use the arrow keys to scroll
down the menu. Information about the animal
age and count is displayed.
Age & Mortality
Age:
10days
New Dead
0
Today's Dead
0

12.2. Current Set Point

1. Select:
» SET POINT / CURVE
1. Set Points
»
Set Point
Current
71.0 °F
Day
70.0 °F
Night
77.0 °F
The current set point is displayed.

12.3. Daily Histories

12.3.1. Heater Daily Run Time His-
tory
The controller keeps a daily heater run time
log for the past 75 days.
1. Select:
» HEATERS / FEEDERS
Heater 1 Run Time
20XX/01/01
30min
2. Press the down-arrow key once to look at
the total run time of the output.
3. Keep pressing on the down-arrow key to
scroll down the run time history of the output.
12.3.2. Resetting the Daily Run
time of a feeder
To reset the run time of a feeder, select the
following menus then follow the prompts
on screen.
1. Select:
» HEATERS / FEEDERS
» 5. Reset Run Time
*This menu is accessible if feeders are enabled (s. 4.5).
2. Use the arrow keys to select the desired
feeder.
Reset Feed.Run Time
Feeder 1 ?
No
Feeder 2 ?
No
Feeder 3 ?
No
3. Press the Edit key then press the up-
arrow key to reset the total running time of
the selected feeder. Press the Edit key once
again to validate. The "Yes" answer switches
to "No" once again, this means the history
has now been cleared.