EXPERT PN110
LCD Contrast
Value
100 %
Min
10 Max
100
2. Press the Edit key then use the arrow
keys to adjust the LCD contrast to the de-
sired value.
3. Press Edit once again to validate. Installation
Setup
The following section shows how to cus-
tomize the controller for your particular
application. It shows how to enable and set
the outputs of your controller. Normally, this
setup needs to be done only once.
1. Select:
» USER
7. Installation*
»
*A password is required to access this menu (sec. 4.2).
Installation
# Feeders
2
# Heater stages
2
Use Hi Fire ?
Yes
# Fan stages
8
# Variables
2
# Clocks
2
# Cycles Clock 1 24
# Cycles Clock 2 24
# 0-10V Outputs
1
Output 1
0-10
Output 1
Vent.
# Curtains
1
Curtain Comp.? Yes
Use Purge ?
No
Hi T° ReStart ? Yes
Use Inlet ?
Yes
Inlet with?
Time
Use OverOpening
Yes
Move In 1 Step
No
Close inlet with
Whisker switch ? No
Use SP Alarm
No
Use Brooder?
Yes
Follow SetPt? Yes
Brooder Mode
Relay
Use Hi Fire ?
Yes
Use Interlock?
No
Allow purge?
Yes
Use Cooling ?
Yes
Use Stir Fan?
Yes
Use Soaking ?
Yes
V1 Min Speed
20
V2 Min Speed
20
V2 Motor Curve
4
Outdoor on Var? Yes
Digit Display
2. Set the following parameters:
Number of Feeders — Enable the proper num-
ber of feeders (0 to 4 feeders).
Number of Heater Stages — Enable the proper
8
EXPERT PN110 rev.23
number of heating stages (0 to 3 stages).
Use HI Fire — Select "Yes" to activate the
heating output Hi fi re option. This function
allows doubling the number of heaters.
Number of Fan Stages — Enable the proper
number of fan stages (3 to 8 stages).
Number of Variable Outputs — Enable the prop-
er number of variable outputs (1 to 2 outputs).
Number of clock outputs — Enable the
proper number of clock outputs (0 to 2 clock
outputs).
Number of clock cycles — If clock outputs
are enabled, select how many timer cycles are
being used by each output (0 to 24 cycles).
0-10V Outputs — Select the number of 0-10V
outputs in use (0 to 2 outputs). * If the 0-10V
brooder is enabled below, the second 0-10V output
will automatically be used to control the brooder
heater.
0-10V Output Signal — Select the signal used
by each 0-10V output (0-10V or 10-0V).
0-10V Output Use — Select the function of
each 0-10V output (Ventilation or heating).
Number of Curtains — Select the proper num-
ber of curtains (1-2). Note that the air inlet
cannot be enabled if both curtains are used.
Curtain Compensation ? — Select "Yes" to use
the curtain compensation.
Use Purge ? — Select "Yes" to use the cur-
tains' purge feature.
Hi T° ReStart ? — Select "Yes" if you want
fans to restart when the room temperature
gets too high in natural ventilation.
Use Inlet ? — Select "Yes" to enable the air
inlet.
Use Inlet with — Select "Pot" if the inlet open-
ing is defi ned by a potentiometer or select
"Time" to control it with a timer. *This param-
eter is accessible if the air inlet is enabled above.
Use OverOpening — A supplementary stage
can be defi ned in order to continue opening
the air inlet beyond the activation tempera-
ture of the last ventilation stage. This over-
opening stage is used to direct the airfl ow
more efficiently during periods of warm
weather. Select "Yes" to enable the inlet over-
opening function or select "No" to disable
it. *This parameter is accessible if the air inlet is
enabled above.
Move in 1 Step — The air inlet can either
reach its over-opening position instanta-
neously when the room temperature reaches
a certain point or it can reach its over-opening
position gradually as the room temperature
departs from the start temperature of the
last fan stage. Select "Yes" to use the instant
opening mode or select "No" to use the
progressive opening mode. Note that either
case, the inlet reaches its full over-opening
position at : On T° of the last fan stage +
Over-Opening bandwidth (see section 6.3).
*This parameter is accessible if the over-opening
function is enabled above.
Close Inlet with Whisker Switch ? — It is
possible to close the air inlet when natural
ventilation curtain #1 is suffi ciently opened.
Select "Yes" to close the air inlet when the
actuator of curtain #1 reaches the Whisker
Switch. *Accessible if the air inlet is enabled above.
Note that the Whisker switch is always associated
with natural curtain #1.
Use SP alarm? — Select "Yes" to use static
pressure alarm. *Accessible if the static pressure
sensor is enabled.
Use Brooder — Select "Yes" to enable a
brooder heater.
Follow SetPt [Brooder] — Select "Yes" if the
operating temperatures of the brooder heater
follow the same variations as the main tem-
perature set points or select "No" if they are
set as absolute values.
Brooder Mode — Select the type of output
that is used to control the brooder heater:
relay or 0-10V output. If the brooder uses a
0-10V output, it must be connected to 0-10V
output #2; if it uses a relay, select the proper
relay in the relay assignment menu (see sec-
tion 4.6.4).
Use HI Fire — Select "Yes" to activate the
brooder Hi fi re option. This function allows
simulating a second brooder output.
Use Interlock? — Select "Yes" if you want the
natural ventilation curtains to close while the