AEMC SIMPLE LOGGER II User Manual page 18

Trms voltage
Hide thumbs Also See for SIMPLE LOGGER II:
Table of Contents

Advertisement

The RED LED is OFF, indicating there is no data in memory
The
PRESS button is used to Start and Stop a Recording
Session
If the
PRESS button is not pressed for a period of one minute, the
instrument will enter a low power STANDBY mode and wait for
either another button press or the recording start time to arrive (if a
recording is scheduled). While in the low power STANDBY mode,
the LEDs will not blink.
A button press of 0.5 seconds will return the unit back to the normal
STANDBY mode
Event: Recording with Memory Cleared
When a recording starts, the logger will continue to record until one of the
following occurs:
The Session is complete
The Memory is full and the recording mode is Start/Stop
PRESS button is pushed until the STOP (ORANGE) LED
The
lights up and is released before the next LED lights
The Stop Recording command from the Simple Logger
Panel is sent to the unit
The battery voltage falls below 1.7V
Event: Recording with a Partial or Full Memory
If the RED LED is double-blinking, the memory must be cleared before
any further recording can be performed.
If the RED LED is single-blinking prior to starting a New Recording Ses-
sion, the memory is partially full.
To save, clear or check memory availability, use the Simple Logger
Control Panel software.
There may be instances where the GREEN LED is also double-blinking
indicating that the logger is still recording. The user can choose to stop
the Recording Session and download the saved session(s) and/or clear
the memory.
NOTE: The logger memory cannot be erased while in the Record mode. The
recording must be stopped first.