  • Page 1 SL261  AC/DC CURRENT OSCILLOSCOPE PROBE E N G L I S H User Manual PowerMeterStore 1.888.610.7664 www. .com Shop for Power Metering products online at:...
  • Page 2 ________________________________ Catalog #: 1201.51 Model #: SL261 Please fill in the appropriate date as indicated: Date Received: _________________________________ _______________________ Date Calibration Due: PowerMeterStore 1.888.610.7664 www. .com Shop for Power Metering products online at:...
  • Page 3: Table Of Contents

    Table of Contents INTRODUCTION ..................2 1.1 International Electrical Symbols ..........3 1.2 Definition of Measurement Categories ........3 1.3 Receiving Your Shipment ............3 1.4 Ordering Information ..............4 1.4.1 Accessories and Replacement Parts ......4 PRODUCT FEATURES ................5 2.1 Description ................5 2.2 Compatibility ................5 2.3 Features ..................6 SPECIFICATIONS ................... 7 3.1 Electrical Specifications ............7 3.2 Mechanical Specifications ............8 3.3 Environmental Specifications ............9 3.4 Safety Specifications ..............9...
  • Page 4: Introduction

    • Do not use the probe if damaged. Always connect the current probe to the measuring device before it is connected around the conductor • Do not use on non insulated conductor with a potential to ground greater than 600V CAT III pollution 2. Use extreme caution when clamping around bare conductors or bus bars. • Before each use, inspect the probe; look for cracks in housing or output cable insulation. • Do not use clamp in wet environment or in locations that hazardous gases exist. • Do not use the probe anywhere beyond the tactile barrier. AC/DC Current Oscilloscope Probe Model SL261 PowerMeterStore 1.888.610.7664 www. .com Shop for Power Metering products online at:...
  • Page 5: International Electrical Symbols

    Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the carrier and notify your distributor at once, giving a detailed description of any damage. Save the damaged packing container to substantiate your claim. AC/DC Current Oscilloscope Probe Model SL261 PowerMeterStore 1.888.610.7664 www. .com Shop for Power Metering products online at:...
  • Page 6: Ordering Information

    Ordering Information AC/DC Current Probe Model SL261 (10A-100mV/A, 100A-10mV/A, BNC) ........Cat. #1201.51 Includes a user manual. 1.4.1 Accessories and Replacement Parts Adapter - BNC Adapter for use with AC/DC Current Probe Model SL261 & Meters 8220, 8333, 8335 & 8336 ....Cat. #2140.40 AC/DC Current Oscilloscope Probe Model SL261 PowerMeterStore 1.888.610.7664 www. .com Shop for Power Metering products online at:...
  • Page 7: Product Features

    CHAPTER 2 PRODUCT FEATURES Description The SL261 AC/DC Current Oscilloscope Probe expands oscilloscope applications in industrial, automotive or power environments, and is ideal for analysis and measurement of distorted current waveforms and harmonics. The probe permits accurate display and measurement of currents from 100mA to 100Arms, DC to 100kHz without breaking into the circuit. The probe uses Hall effect technology to measure AC and DC signals. The probe connects directly to an oscilloscope through a 2 meter coaxial cable with an insulated BNC. Compatibility The Model SL261 is compatible with any analog or digital oscilloscope or other voltage-measuring instrument which has the following features: • BNC input connector • Range capable of displaying 0.2 to 0.5V per division • Minimum input impedance of 1MΩ AC/DC Current Oscilloscope Probe Model SL261 PowerMeterStore 1.888.610.7664 www. .com Shop for Power Metering products online at:...
  • Page 8: Features

    Peak Overload Indication LED Battery Compartment Battery Screw Compartment Cover WARNING: Always keep hand on the handle part of the probe. AC/DC Current Oscilloscope Probe Model SL261 PowerMeterStore 1.888.610.7664 www. .com Shop for Power Metering products online at:...
  • Page 9: Specifications

    (40A to 80A DC/AC 10mV/A 15% of reading peak) (80A to 100A DC/AC Frequency Range: DC to 100kHz (-3dB with current derating) Noise: Range 10mV/A: 480µV Range 100mV/A: 3mV Slew Rate: Range 10mV/A: 20mV/µs Range 100mV/A: 0.3V/µs Load Impedance: > 1MΩ/100pF AC/DC Current Oscilloscope Probe Model SL261 PowerMeterStore 1.888.610.7664 www. .com Shop for Power Metering products online at:...
  • Page 10: Mechanical Specifications

    Drop Test: 1.0m on 38mm of oak on concrete; test according to IEC 1010 Mechanical Shock: 100G; test per IEC 68-2-27 Vibration: Test per IEC 68-2-6, frequency range 10 Hz to 55 Hz, amplitude 0.15mm 920A, UL 94 V2 ® Handle: Lexan Dimensions: 9.09 x 1.42 x 2.64" (231 x 36 x 67mm) Weight: 11.6 oz (330g) with battery Color: Light gray Output Lead: Insulated coaxial cable with insulated BNC connector Cable Length: 6.5 foot (2m) AC/DC Current Oscilloscope Probe Model SL261 PowerMeterStore 1.888.610.7664 www. .com Shop for Power Metering products online at:...
  • Page 11: Environmental Specifications

    Electromagnetic Compatibility: EN 50081-1 Class B EN 50082-2 Electrostatic discharge IEC 1000-4-2 Radiated Field IEC 1000-4-3 Fast Transients IEC 1000-4-4 Magnetic Field at 50/60 Hz IEC 1000-4-8 *Specifications are subject to change without notice AC/DC Current Oscilloscope Probe Model SL261 PowerMeterStore 1.888.610.7664 www. .com Shop for Power Metering products online at:...
  • Page 12: Typical Response Curves

    100000 phase in ° Frequency in Hz range 10 mV/A -100 phase graph measurement current: 1A sine -150 range 100 mV/A Phase Shift AC/DC Current Oscilloscope Probe Model SL261 PowerMeterStore 1.888.610.7664 www. .com Shop for Power Metering products online at:...
  • Page 13 Typical Specification -10% -12% -14% -16% 100A Accuracy AC/DC Current Oscilloscope Probe Model SL261 PowerMeterStore 1.888.610.7664 www. .com Shop for Power Metering products online at:...
  • Page 14: Operation

    The probe has a zero adjustment that should be adjusted before measurement. Alternatively, you may “zero” with the oscilloscope instead. Current Measurement WARNING: Always connect the probe to the instrument before clamping onto the circuit under test. • Connect the Model SL261 to the proper input channel on the oscilloscope. • Begin with the least sensitive range on the current probe (10mV/A). • Select the 0.5V/Division range on the oscilloscope.
  • Page 15: Battery Indication (Green Led)

    Battery Indication (Green LED) The probe has a battery condition LED. To ensure proper readings with your current probe, be sure that the green LED is lit during measurement. If not, replace the 9V battery. Peak Overload (OL) Indication (Red LED) The SL261 offers an overload indicator. If the red LED illuminates during measurement, this indicates that the peak value exceeds the instrument response level and that the output is distorted. Switch the probe to a higher range if possible. AC/DC Current Oscilloscope Probe Model SL261 PowerMeterStore 1.888.610.7664 www. .com Shop for Power Metering products online at:...
  • Page 16: Maintenance

    (isopropanol) or ethyl alcohol (fotocol or ethanol). Lubricate the jaws mating surfaces with a light oil. • Do not use chemicals containing benzine, benzene, toluene, xylene, acetone, or similar solvents. • Do not immerse the probe in liquids or use abrasive cleaners. AC/DC Current Oscilloscope Probe Model SL261 PowerMeterStore 1.888.610.7664 www. .com Shop for Power Metering products online at:...
  • Page 17: Replacing The Batteries

    If the green battery indication LED does not light up when the probe is turned on, the batteries will need to be replaced. Do not replace the battery while probe is in use. To replace the battery: • Disconnect the probe from the circuit and the oscilloscope. • Turn the probe “OFF”. • Unscrew the battery compartment screw and pull out the battery compartment cover. • Replace the battery and put the cover back on. AC/DC Current Oscilloscope Probe Model SL261 PowerMeterStore 1.888.610.7664 www. .com Shop for Power Metering products online at:...
  • Page 18: Repair And Calibration

    NOTE: You must obtain a CSA# before returning any instrument. Technical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your instrument, please call, fax or e-mail our technical support AC/DC Current Oscilloscope Probe Model SL261 PowerMeterStore 1.888.610.7664 www. .com Shop for Power Metering products online at:...
  • Page 19: Limited Warranty

    Limited Warranty The AC/DC Current Oscilloscope Probe Model SL261 is warranted to the owner for a period of two years from the date of original purchase against Instruments, ® defects in manufacture. This limited warranty is given by AEMC not by the distributor from whom it was purchased. This warranty is void if the unit has been tampered with, abused or if the defect is related to service not Instruments. performed by AEMC ® a malfunction occurs within the warranty period, you may return the instrument to us for repair, provided we have your warranty registration information on file Instruments will, at its option, repair or replace or a proof of purchase. AEMC ®...