AEMC J93 User Manual

Compatible current probes & sensors for power quality meters
Hide thumbs Also See for J93:

Advertisement

Quick Links

99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
COMPATIBLE CURRENT
n
PROBES & SENSORS FOR
POWER QUALITY METERS
E N G L I S H
User Manual
193-24-BK
193-36-BK
MA193-10-BK
MA193-14-BK
MN93-BK
MN193-BK
MR193-BK
SL261-BK
SR193-BK
J93

Advertisement

Table of Contents
loading

Summary of Contents for AEMC J93

  • Page 1 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 193-24-BK Visit us at www.TestEquipmentDepot.com 193-36-BK COMPATIBLE CURRENT PROBES & SENSORS FOR POWER QUALITY METERS MA193-10-BK MA193-14-BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK E N G L I S H User Manual...
  • Page 2 Thank you for purchasing an AEMC current probe. For best results from your instrument and for your safety, read the enclosed operating instructions carefully and comply with the precautions for use. These products must be only used by qualified and trained users.
  • Page 3: Precautions Before Use

    PRECAUTIONS BEFORE USE The protection assured by the current probe can be compromised if it is used in a way that is not recommended by the manufacturer. ■ Comply with the rated maximum voltage and current, and the measurement category. Do not use the current probe on networks where the voltage or category exceeds those specified.
  • Page 4 ® 2.1.2 MiniFlex Model MA193-BK .............6 ® 2.1.3 AC/DC Current Probe Model J93 ..........7 2.1.4 AC Current Probe Models MN93-BK & MN193-BK ....8 2.1.5 AC Current Probe Model MR193-BK ........9 2.1.6 AC Current Probe Model SL261 ..........10 2.1.7 AC Current Probe Model SR193-BK ........11 3.
  • Page 5: Introduction

    Save the damaged packing container to substantiate your claim. 1.2 Ordering Information NOTE: The current probes in this manual are compatible only with AEMC Power ® Analyzers (see § 4 for meter compatibility).
  • Page 6: Product Features

    2. PRODUCT FEATURES 2.1 Control Features 2.1.1 AmpFlex Model 193-24-BK & 193-36-BK ® Flexible sensor Sensor opening connector Shielded lead Custom 4-pin input connector Current Probes & Sensors for Power Quality Meters...
  • Page 7 2.1.2 MiniFlex Model MA193-BK ® Flexible sensor Sensor opening device Shielded lead Custom 4-pin input connector Current Probes & Sensors for Power Quality Meters...
  • Page 8: Ac/Dc Current Probe Model J93

    2.1.3 AC/DC Current Probe Model J93 ZERO 300 V CA T IV 600 V CA T III Jaws 4-point CA connector Safety guard Zero adjustment knob Power ON/Low battery indicator Three-position switch: ON, OFF, battery test Current Probes & Sensors for Power Quality Meters...
  • Page 9: Ac Current Probe Models Mn93-Bk & Mn193-Bk

    2.1.4 AC Current Probe Models MN93-BK & MN193-BK Jaws Protective guard Two-position range switch (MN193 only) Jaw opening lever Shielded lead Custom 4-pin input connector Current Probes & Sensors for Power Quality Meters...
  • Page 10: Ac Current Probe Model Mr193-Bk

    2.1.5 AC Current Probe Model MR193-BK Jaws Protective guard Jaw opening lever Two-position range switch Shielded lead Zero adjustment Custom 4-pin input connector Current Probes & Sensors for Power Quality Meters...
  • Page 11: Ac Current Probe Model Sl261

    2.1.6 AC Current Probe Model SL261 Jaws Zero adjust knob Range selection switch Battery compartment screw Battery compartment cover BNC Adapter (sold separately - Cat. #2140.40) Current Probes & Sensors for Power Quality Meters...
  • Page 12: Ac Current Probe Model Sr193-Bk

    2.1.7 AC Current Probe Model SR193-BK Jaws Protective guard Jaw opening lever Shielded lead Custom 4-pin input connector Current Probes & Sensors for Power Quality Meters...
  • Page 13: Operation

    3. OPERATION The current probes and flexible sensors are used to measure the current flowing in a conductor or bus bar without opening the circuit. They also insulate the user from dangerous voltages in the circuit. The choice of current probe or sensor to be used depends on the amperage to be measured and the diameter of the cables or size of the bus bar.
  • Page 14 For Probes: ■ Press the jaw opening lever on the probe to open the jaws. ■ Clamp the probe around the conductor to be tested. For best results, center the conductor in the jaws of the clamp. For AmpFlex and MiniFlex Sensors: ®...
  • Page 15: Specifications

    Battery: 9V Alkaline NEDA 1604A, 6LR61 Battery Life: MR193 - 100H typical SL261 - 55H typical J93 - 70H typical NOTE: Battery life is twice the typical value when using Lithium batteries Current Probes & Sensors for Power Quality Meters...
  • Page 16: Environmental

    4.2 Environmental Indoor use. Operating Temperature: 14° to 131°F (-10° to 55°C); 10% to 85% RH Storage Temperature: -40° to 158°F (-40° to 70°C); 10% to 90% RH Degree of pollution: 2 Altitude: < 2000 m 4.3 Mechanical Clamping Lead Length Model Dimensions Weight...
  • Page 17: Safety

    AmpFlex 1000V CAT III; 600V CAT IV ® MiniFlex 1000V CAT III; 600V CAT IV ® J93: 600V CAT III; 300V CAT IV MN93 / MN193: 600V CAT III; 300V CAT IV MR193: 600V CAT III; 300V CAT IV SL261:...
  • Page 18: Maintenance

    5. MAINTENANCE Use only factory specified replacement parts. AEMC will not be held responsible ® for any accident, incident, or malfunction following a repair done other than by its service center or by an approved repair center. CAUTION: Risk of electric shock. Disconnect the instrument from any source of electricity.
  • Page 19: Model J93

    5.2.3 Model J93 ■ Insert a tool, not more than 3mm in diameter, in the hole in the battery compartment cover. ■ Push to unlock the battery compartment cover, then slide it off. ■ Remove it completely by hand. ■ Remove the battery and the shim from the compartment.
  • Page 20: Limited Warranty

    Instruments, not by the distributor from whom it was ® purchased. This warranty is void if the unit has been tampered with, abused or if the defect is related to service not performed by AEMC Instruments. ® Please print the online Warranty Coverage Information for your records.
  • Page 21 05/15 99-MAN 100391 v3 Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com...

Table of Contents