Siruba BH9820 Operation Manual page 17

Table of Contents

Advertisement

2.3.4 List of Pattern Parameters at S level
According to the set content of other parameters, the default value of some parameters
may be unchangeable or invalid.
Parameter
Content
Number
S01
Sewing Speed
Length of Lockstitch Sewing
S02
at Buttonhole
S03
Cutter Interval
S04
Stitch Pitch
Stitch Number at Eyelet Part
S05
S06
Length of Taper
S07
Offset
Length of Linear Bar-tacking
S08
Stitch Number of Linear
S09
Bar-tacking
Stitch Number of Round
S10
Bar-tacking
S11
Shape of Cutter
Sewing Width Adjustment
S12
Eyelet Part Low
S13
Speed of Linear Bar-
S14
tacking
Stitch Number of Slow-start
S15
Range
1000~2700rpm
5~50m
m
-2.5~0.5mm
0.5~2.0mm
4~20 Stitches
1~20m
m
0.5~2.0mm
2.0~6.0m
m
(Each side at 3.0mm as
5~18 Stitches
5~17 Stitches
1~6
(select the proper cutter
number, according to the
different cutter)
-1.0~1.0mm
-
600~0rpm
Speed
(This parameter takes the
default value of the
parameter 01 sewing
d
t
1000~2500rp
m
(if the sewing speed
is lower than the linear
bar-tacking speed, the
linear bar-tacking speed
will be the same as the
i
0~3 Stitches
9
Default
Unit
Value
100
1800rpm
0.5
25mm
0.05
0.2mm
0.1
1.0mm
1
9 Stitches
1
6mm
0.1
1.5mm
0.1
5.0mm
1
7 Stitches
1
7 Stitches
1
0.1
0.0mm
100
0rpm
d d )
100
1800rpm
d )
1
0 stitch
2

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents