Lift Capacity Indication - PROLEC Liftwatch Rail Operator's Manual

Rated capacity indicator
Table of Contents

Advertisement

2.2 Load capacity indication
Safe Load
The suspended load is less than 92.5%
of the maximum safe working load.
The HOOKLOAD symbol along with
the current suspended load is
displayed.
No alarms or warning messages are
issued.
Liftwatch Rail Operators Manual 560386-000 Issue 1.2 © Prolec Ltd - Feb 2011
Approach to maximum safe load
The suspended load is greater than
92.5% but less than 97.5% of the
maximum safe working load.
A screen warning is issued, the amber
LED will flash and the internal alarm
will activate.
2
Overload
The suspended load is greater than
102.5% of the maximum safe working
load.
A screen warning is issued, the red
LED will flash and the internal and the
external alarms will activate.
Motion control of the machine will
operate, the graphic denoting which
motions have been cut and which are
active.