Vertical And Lateral Measurements - PROLEC Liftwatch Rail Operator's Manual

Rated capacity indicator
Table of Contents

Advertisement

2.6 Vertical and lateral measurements

Position measurement
Liftwatch Rail measures equipment pin positions using equipment mounted angle sensors. All positions are corrected for chassis pitch (rail gradient), roll (rail
cant) and slew.
WARNING
For In-Gauge calculation the system is unaware of any additional attachments (bucket, ballast broom etc). Only the bucket pin radius, highest
point and counter weight corners are monitored.
Height Limit
Highest point
= Equipment
extremes
measured by the
system
NB to account for
extra equipment
and pipework etc,
both the bucket pin
and arm ram pin
can use an
optional vertical
safety 'offset'
determined during
RCI set-up and
calibration.
Liftwatch Rail Operators Manual 560386-000 Issue 1.2 © Prolec Ltd - Feb 2011
Radius
Slew centre line