16. Touch screen calibration

Liftwatch Rail features a touch screen display and will have been delivered in a pre-calibrated state. Should the touch screen
calibration be corrupted or the physical properties of the actual touch screen change, then re-calibration will be necessary. If a
corrupted calibration is detected the system will automatically launch the re-calibration function on start up. The re-calibration
option can be manually accessed either via the system set-up, or by pressing the recalibration button three times in succession
during normal operating mode.
Liftwatch Rail Operators Manual 560386-000 Issue 1.2 © Prolec Ltd - Feb 2011
Once accessed the re-cal
function will start to 'countdown'.
If no action is taken within 10
seconds the re-calibration
procedure will terminate. Press
soft key 1 to exit. If a re-
1
calibration is required use a
suitable stylus (e.g. Pen, not a
finger) to touch the screen as
indicated by the cross-hairs.
Press and hold for around 5
seconds to allow the software to
'sample' the position, then lift the
stylus.
Calibration is now
3
complete. To verify the
accuracy touch the
screen at any point. The
cross-hairs should
appear at the point of
contact. If the accuracy is
unacceptable, exit the
function, and try again.
The cross-hairs will automatically
move to the lower right of the screen.
Press and hold for
2
around 5 seconds to
allow the software to
Once calibration is complete (or the
'countdown' has expired) there is an
opportunity to adjust the touch screen
pressure sensitivity. Use the PRESSURE
softkey 5 to access pressure adjustment. The
lower the value, the more sensitive the
screen will become. If the required pressure
value falls outside a range of around 80 to
1024 contact Prolec Ltd as the operation/
durability of the unit may be in question.
'sample'
the new
position,
then lift
the stylus.