14.1 Data extraction

Logged data can be extracted from Liftwatch Rail, a passcode held by Prolec Ltd and the machine convertor/service agreement holder is needed to upload
this data.
Directory structure
FILES
FOLDERS
Both event and periodic logger files are in a
binary format. The periodic logger files are also
compressed. A Microsoft Windows® application
is available from Prolec Ltd to convert these files
in a CSV format suitable for import into a
spreadsheet application.
Event log archive (no limit to number)
Periodic log archive (no limit to number)
Archive folders are named using the date when they were
Liftwatch Rail Operators Manual 560386-000 Issue 1.2 © Prolec Ltd - Feb 2011
C:\
RR
HISTORY.LOG
HIST0001.LOG
HIST0002.LOG
. . . . . .
HIST0010.LOG
PERIOD.LOG
PERIOD01.LOG
PERIOD02.LOG
. . . . . .
PERIOD99.LOG
07$06$10.EVT
07$06$10.PRD
created.
'Active' event logging file
Earlier event logging files, maximum 10. If files are not
archived when the maximum has been reached will start to
'rotate' (oldest data will be lost)
'Active' periodic logging file
Earlier periodic logging files, maximum 99. If files are not
archived when the maximum has been reached will start to
'rotate' (oldest data will be lost)
HISTORY.LOG
PERIOD.LOG
HIST0010.LOG
PERIOD99.LOG