4.3.4

Multifamily house with a medical practice

In a "ABB-AccessControl" system the main entrance and the entrances to the apartments in a
multifamily house are equipped with "Electronic cylindrical lock"
The building contains a medical practice. The archive in the basement should also be equipped
with an "Electronic cylindrical lock" for the medical practice. There is no radio connection to this
room.
Aside from the "Electronic cylindrical lock" a "Smart Access Point Pro" is necessary for the user
management.
The ceiling of the floor greatly reduces the transmission range of the radio signals. That is why
the additional use of an "RF/IP Gateway" is required for the distribution of data for each
additional floor.
In this example the "Smart Access Point Pro" is already available (e.g. in a "ABB-Welcome
IP"). That is why it is also being used. The power for the "Smart Access Point Pro" and the
"RF/IP Gateway" is supplied via the PoE switch.
Upper building:
The distances within a floor are within the radio range of around 10 meters. That is why
additional devices to increase the range are not required within the floors.
Detailed information about the capacity and network planning is available at: see chapter 4.2
"Capacity / Transmission range" on page 65
Basement with archive:
The installation of an increase of the transmission range into the basement is not available.
Since there is no radio connection between the "Electronic cylindrical lock" and the "Smart
Access Point Pro", the emergency function must in this case be set up in the user management
for the necessary "Electronic cylindrical lock" and the associated transponder key. The
emergency function allows the archive then to be opened and closed without a radio connection
to the "Smart Access Point Pro".
To set up the emergency function an initial radio connection of the "Electronic cylindrical
lock" to the "Smart Access Point Pro" is required. E.g. by dismantling the reading head from
the "Electronic cylindrical lock". To set up the emergency function the reading head is then
positioned in close proximity of the "Smart Access Point Pro".
To set up the emergency function in the management software of the "Smart Access Point
Pro" see chapter 5.3.3 ""Electronic cylindrical lock" Settings ‒ Emergency function" on page