4.3.2

Multifamily house with one floor

In a "ABB-AccessControl" system the main entrance and the entrances to the apartments in a
multifamily house are equipped with "Electronic cylindrical lock"
Aside from the "Electronic cylindrical lock" a "Smart Access Point Pro" is necessary for the user
management.
The "ABB-AccessControl" system in this example is not networked with other systems. The
use of a PoE switch is not planned, and that is why the "Smart Access Point Pro" a separate
24 V power supply.
The distances are within the radio range of around 10 meters. That is why additional devices to
increase the range are not required.
Up to 16 "Electronic cylindrical lock" can be activated via a "Smart Access Point Pro". If the total
number of the "Electronic cylindrical lock" is smaller, additional devices to increase the capacity
are not required.
Detailed information about the capacity and network planning is available at: see chapter 4.2
"Capacity / Transmission range" on page 65
Fig. 57:
Overview: Multifamily house with 3 "Electronic cylindrical lock"
System Manual 2CKA001473B5074
Information about planning and application
24 V DC
~10 m
~10 m
~10 m