Dismantling Old Cylindrical Locks - ABB AccessControl System Manual

Table of Contents

Advertisement

2.3.8

Dismantling old cylindrical locks

Aside from the normal local standard cylinders, also other cylinder systems are used when the
situation requires it. If for the use of the "ABB-AccessControl" old cylindrical locks must be
removed, you will find information in the following about the dismantling of conventional
cylindrical locks.
Dismantling old cylinders: Profile Europe (EU) and Switzerland (CH)
3.
Fig. 15: Dismantling old cylinders: Profile Europe (EU) and Switzerland (CH)
To dismantle the existing old cylinders, perform the following items:
1. Turn the driver down vertically.
2. Screw out the forend screw.
3. Remove the cylinder.
Dismantling old cylinders: Profile Scandinavian oval
2.
Fig. 16:
Dismantling old cylinders: Profile Scandinavian oval
To dismantle the existing old cylinders, perform the following items:
1. Dismantle the head on the interior side.
2. Dismantle the mounting set of the cylindrical lock on the interior side.
3. Remove the cylinder on the exterior side.
System Manual 2CKA001473B5074
2.
1.
1.
Overview of product range
3.
│28