Commissioning The "Smart Access Point - ABB AccessControl System Manual

Table of Contents

Advertisement

The graphics illustrate two basic areas within buildings (here a residential building). Both areas
of the installation are strictly separated by the first indoor station (master) of a unit which
operates as IP gateway. No area can access the other area.
Area [A]: The public area (building network)
Here, for example, the caretaker receives the visitors and guides them to the individual
apartments.
Area [B]: The private area (units network)
This area is, as the name indicates, private. The public area cannot access the private
area from behind the 1st indoor station. Access is also not possible from the private
area to the public area.
System modes of the "Smart Access Point"
For the later adding of the devices the system mode must already be specified during the
processing steps of the commissioning of the "Smart Access Point".
Mode "Multi-unit house / commercial":
For a building network.
The "Smart Access Point" is located in the building network.
The "Smart Access Point" has the static IP address "10.0.0.1".
The 10s IP address range is used to communicate with the "ABB-Welcome IP"
participants.
In parallel the "Smart Access Point" can be connected with a router per WLAN or
LAN and act as DHCP Client. Here the device receives an additional IP address
assigned by the router. This it uses in addition to its own 10s IP address.
Mode "One-family house / terraced house":
For a units network.
The "Smart Access Point" is located in the units network.
The "Smart Access Point" has the static IP address "10.0.0.1".
The 10s IP address range is used to communicate with the "ABB-Welcome IP"
participants.
In parallel the "Smart Access Point" can be connected with a router per WLAN or
LAN and act as DHCP Client. Here the device receives an additional IP address
assigned by the router. This it uses in addition to its own 10s IP address.
3.1.4

Commissioning the "Smart Access Point"

When the "Smart Access Point" is connected to the PC and the start page of the "Smart Access
Point" is called up in the browser, the "Smart Access Point" is ready for commissioning.
During commissioning a wizard guides through the individual steps.
Commissioning must be carried out in the following situations:
For initial commissioning
After a reset to the factory settings
To commission the device, perform the following steps: