Safety functions
Emergency shutdown
Logic level: 3.3 V/TTL (5V tolerant)
Active with logic low (for AUX2/SHDNn pin)
Emergency shutdown sources: SHDNn, PXI star trigger input, PXI
trigger bus
Watchdog timer
Base clock available: 10MHz, fixed
Counter width: 32-bit
Watchdog Timer Overflow sources: Onboard 32-bit watchdog
timer, PXI star trigger input, PXI trigger bus
General Specifications
I/O Connector: 62-pin D-sub male
Operating temperature: 0 to 55°C
Storage temperature: -20 to 70°C
Humidity: 5 to 95% non-condensing
Power requirements (when all relays are activated simultaneously)
Dimensions (not including connectors)
160 mm x 100 mm

1.4 Software Support

ADLINK's ADL-SWITCH driver package is for Microsoft Windows operating
systems, including Windows 98/ME/NT/2000/XP.
The driver package also provides utilities to test your switch module, as well as
programming samples and source codes in Microsoft Visual Basic and Visual
C/C++.
For other operating systems, please contact ADLINK for more information.
+5V
1A
+3.3V
400mA