11.15

AC input specifications

11.15.1

General AC input specifications

Parameter
Input AC power connection
Earthing systems
Input voltage range
Power factor at full load
Efficiency
Total harmonic distortion (current)
Short circuit current rating
11.15.2

AC input specifications (Terra Mobile 44HV)

Parameter
Maximum rated input current
Recommended input circuit breaker
Maximum power dissipation
11.15.3

AC input specifications (Terra Mobile 54HV)

Parameter
Maximum rated input current
Recommended input circuit breaker
Maximum power dissipation
11.15.4

General AC input cable specifications

Parameter
Surface and diameter
Material
Maximum temperature of the input ca-
bles
Minium length
11.15.5

AC input cable specifications (Terra Mobile 44HV)

Parameter
Cross section of the phase conductors
Cross section of the PE conductor
Diameter of AC cable, including shielding 14.5 - 36 mm
Suggested single phase wire cross-sec-
tion
9AKK108467A6997-EN | 003
Specification
3P + N + PE
TN
400 VAC +/- 10% (50 Hz)
>0.96
>94% at nominal output power
<5%
65 kA
Specification
62 A
63 A
43 kVA
Specification
78 A
80 A
54 kVA
Specification
Based on current rating of the EVSE and
local regulations
Copper
75 °C (167 °F)
n + 1 m, where n is the distance between
the power source and the EVSE
Specification
5x16 mm²
16 mm²
16 mm²
Technical data
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Terra mobile 54hv

Table of Contents