Overview of the error codes (Europe)

If the EVSE detects a problem, the error LED comes on. The mobile app shows the
error description.
Short description
Overcurrent
Overvoltage
Undervoltage
Internal board to board
communication error
Residual current error
(DC 6mA)
Residual current moni-
tor selftest error
Relay stuck error
Cable under capacity
Missing earth error
Overheat
Missing phase
2.8.5

Overview of the error codes (North America, Terra AC Wx-P8-xxxxx)

If the EVSE detects a problem, the error LED comes on. The mobile app shows the
error description.
Short description
Overcurrent
Overvoltage
Undervoltage
Internal board to board
communication error
Residual current error
(AC 30mA)
CCID (AC 20 mA)
Residual current moni-
tor selftest error
Relay stuck error
Cable under capacity
22
Description
To connect the EVSE to the power grid of the site net-
work.
To add and bind RFID cards
Description
There is an overload on the EV side.
The maximum voltage input from the grid is exceeded.
The voltage input from the grid is not sufficient.
The internal boards of the EVSE fail to communicate with
each other.
There is residual current in the charge circuit. Current
leaks into the ground.
The residual current monitoring sensor is defective.
The relay contact is overheated or has damage.
On the socket version of the EVSE, the rated current ca-
pacity of the cable is less than the rated current of the
EVSE.
The EVSE is not earthed correctly.
The charging current is too high.
B and C phase are missing or one of these phases is
missing.
Description
There is an overload on the EV side.
The maximum voltage input from the grid is exceeded.
The voltage input from the grid is not sufficient.
The internal boards of the EVSE fail to communicate with
each other.
There is residual current in the charge circuit. Current
leaks into the ground.
The residual current monitoring sensor is defective.
The relay contact is overheated or has damage.
On the socket version of the EVSE, the rated current ca-
pacity of the cable is less than the rated current of the
EVSE.