Table 1: Cable lugs
Loca-
tion
Power
cabi-
net
Charge
post
12.5

General specifications

Parameter
Compliance and safety
Ingress protection rating
EMC rating for the charge post
EMC rating for the power cabinet
12.6

Electrical installation specifications (North America)

Parameter
Upstream overcurrent protection device Fuse (gG type) 300 A
Surge protection device within the up-
stream power distribution system
Power consumption of the power cabi-
net
Power consumption of the charge post
Earthing rod (initial)
Earthing rod (additional)
Input AC power connection
Input grounding system
9AKK107992A3069-EN | 004
Wire
Size
PE
M12
M10
M6
AC input power M12
DC power
M12
PE
M8
M6
DC power
M12
Maximum
Maximum
width
length
[mm]
[in]
[mm]
35
1.4
70
25
70
50
12
0.5
40
39
1.5
70
39
1.5
70
22
0.9
40
12
0.5
40
39
1.5
40
Specification
UL 2202
CSA STD C22.2 No. 107.1
FCC Part 15 Class A
TuV certified
The type plate shows the specification.
Refer to section 3.2.
FCC part 15 Class B (residential)
The power cabinet complies with Class A
(industrial).
If the power cabinet must comply with
Class B (residential), install an external
Schaffner type FN 3359HV-400-99 EMC
filter.
Specification
According to UL 1449
In standby status: ≤ 80 W
In standby status: ≤ 70 W
With the LEDs on: ≤ 145 W
Maximum 10 Ω
0.9 Ω
480/277 3W + PE
wye Grounded system
Technical data
Bolt hole size
[in]
[mm]
[in]
2.7
13
0.5
70
11
0.4
1.6
6.5
0.3
2.7
13
0.5
2.7
13
0.5
1.6
8.5
0.4
1.6
6.5
0.3
1.6
13
0.5
69