RRU3832&RRU3632
Installation Guide
If an RRU is installed on the bitumen ground, the RRU must be at least 500 mm (700 mm or
more as recommended) away from the bitumen ground. The following describes the space
requirements for installing multiple RRUs on the non-bitumen ground.
Recommended Clearances for Three or More RRUs Installed on a Pole
Figure 3-28
mode.
Figure 3-28 Recommended clearances for three or more RRUs installed on a pole
Minimum Clearances for Three or More RRUs Installed on a Pole
Figure 3-29
Issue 05 (2014-06-30)
NOTICE
NOTE
l The recommended clearances ensure normal running and provide an appropriate space for operation
and maintenance (OM). If there is sufficient space, retain the recommended clearances.
l The minimum clearances ensure normal running and heat dissipation but do not allow OM activities
such as checking indicator status and opening the cabling cavity. If the installation space is insufficient,
retain the minimum clearances after the installation.
shows the recommended clearances for multiple RRUs installed in centralized
shows the minimum clearances for multiple RRUs installed in centralized mode.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 Information About the Installation
30