4.4 Data Report

When the device is turned on, it will immediately send a version package.
Data will be reported once per hour by default setting.
Maximum time: 3600s
Minimum time: 3600s (Detect the current voltage value every 3600s by default setting)
Default reportchange:
Battery ---- 0x01 (0.1V)
Note:
The device send data cycle depends on real burning configuration.
The interval between two reports must be the minimum interval.
Data report configuration and sending period are as following:
Min. Interval
(Unit:second)
Any
number
between 1~65535

5. Restore to Factory Setting

R718KA saves data including network key information, configuration information, etc. To restore to
factory setting, users need to execute below operations.
1. Press and hold function key for 5 seconds till the green indicator flashes and then release; LED
flashes quickly 20 times.
2. R718KA is at off mode by default setting after restoring to factory setting.
Note: The device operation of turning off is the same as the "Restore Factory Settings" operation.

6. Sleeping Mode

R718KA is designed to enter sleeping mode for power-saving in some situations:
(A) While the device is in the network → the sleeping period is Min Interval.
Max. Interval
Reportable
(Unit:second)
Change
Any
number
Can not be 0.
between 1~65535
Current
Change≥
Reportable Change
Report
per Min. Interval
5
Current
Change <
Reportable Change
Report
per Max. Interval