Connecting The Air Cooling For Hipace 60 P, Hipace 80, And Split; Fig. 8: Fitting The Mounting Bracket For Air Cooling; Fig. 9: Mounting The Air Cooling Onto The Bottom Part - Pfeiffer Vacuum HiPace Operating Instructions Manual

Table of Contents

Advertisement

4.2.1 Connecting the air cooling for HiPace 60 P, HiPace 80, and SplitFlow 50
Prerequisites
● Turbopump switched off and flooded
Required tools
● Allen key, WAF 2.5
● Allen key, WAF 3
Fig. 8:
1 Mounting bracket
2 Interior hexagon socket screw
Fitting the mounting bracket
1. Screw the mounting bracket onto the pump bottom part with 2 interior hexagon socket screws.
2. Attach the fan housing to the mounting bracket.
A
3
Fig. 9:
1 Rubber foot
Mounting the air cooling onto the bottom part
The method of mounting onto the pump bottom part differs depending on whether rubber feet are being
used.
1. A: Mounting with rubber feet: Secure the fan housing using one rubber foot without washer.
2. Level the 3 remaining rubber feet with a washer inserted for each.
3. B: Mounting without rubber feet: Attach the fan housing with the countersunk screw.
2
1
Fitting the mounting bracket for air cooling
1
2
Mounting the air cooling onto the bottom part
2
Washer
1
3
Air cooling
B
3
4
Installation
2
3
15/26