List Of Input Commands; Command Reference - Omron F10-C20 Instruction Sheet

Pattern matching sensor amplifier
Hide thumbs Also See for F10-C20:
Table of Contents

Advertisement

8.3 List of Input Commands 
■  Specifying F10 Operation 
The following commands specify the operation of the F10, such as executing a 
measurement, changing the bank number, etc. 
 
 
Command 
Function 
 
BC 
Change bank number. 
 
MD 
Acquire previous measurement result. 
 
ME 
Execute image capture measurement once only. 
 
 
Begin continuous or synchronous measurements. 
 
 
Execute measurement of image in image memory once only. 
 
 
Stop measurement. 
 
RT 
Reset. 
 
TC
Execute teaching.
 
■  Saving/Loading data 
The following commands back up data that has been set using F10. 
 
 
Command 
Function 
 
BL 
Transfer bank data from external device (load). 
 
BS 
Transfer bank data to external device (save). 
 
SG 
Acquire system data. 
 
SS
Set system data.
 
■  Acquiring or Changing Current Settings 
The following commands acquire threshold levels or other setting or change the 
settings.The host can use these commands to determine F10 settings, as well 
as modify values and specify operation.
 
Command 
Function 
BA 
Acquire the current bank number. 
HT 
Acquire the head type. 
MC 
Change the signal/serial priority mode. 
MM 
Acquire the measurement mode. 
LS 
Set the threshold level. 
LG
Acquire the threshold level.
39
8.4 Command Reference
Command  formats  are  explained  below  in  alphabetical  order.
Commands are input in ASCII. Only uppercase characters can be used.
The space character ($20) displays as "̲" (under-bar) in this command
reference.
----------------------------------------------------------------------------------------------
■ BA -BAnk- : Acquire current bank number
----------------------------------------------------------------------------------------------
BA acquires the current bank.
Input Command
@<unit̲number>BA[CR]
・ Set the following numerical values for <unit̲number>.
 
Unit No. 
Content 
00 to 31
Unit number of the Unit whose bank number is sought.
Output Response
@<unit̲number>BA̲<bank̲number>[CR]:Executed correctly
<unit̲number>
00 to 31: Unit number of Unit to 
acquire bank number
<bank̲number>
00 to 07: Bank number
Example
To acquire the current bank in Unit 0 (when the bank number is 1):
Input: @00BA[CR]
Output: @00BA̲01[CR]
----------------------------------------------------------------------------------------------
■ BC -Bank Change- : Change bank number
----------------------------------------------------------------------------------------------
BC changes the bank number to a specified bank number.
Input Command
@<unit̲number>BC̲<bank̲number>[CR]
・ Set the following numerical values for <unit̲number>.
 
Unit No. 
Content 
00 to 31
Unit number of the Unit whose bank number is sought.
40