TROUBLE
All machine functions do not operate
No drive function when platform fully low-
ered. Lift function okay
No drive function when platform elevated.
Lift function okay
Machine cannot lift down. Lift up function
okay
3-2
Table 3-1. Electricl Troubleshooting Chart
PROBABLE CAUSE
Emergency stop switch not activated
Joystick not in neutral position
Platform cable not connected to platform box
or at base
Battery voltage out of range
If battery cahrger is plugged in
Battery voltage too low
Line contactor open circuit
Loose wiring connections on line contactor or
at harness connection
Open coil on line contactor
Faulty wiring at base
Line contactor welded.
Line contactor or other driver short circuit or
tripped
Point A short circuit
Motor stalled
Motor open circuit
Faulty motor
Malfunctioning limit switch
Malfunctioning limit switch
Platform above drive cutout height
Loose wiring on lift cylinder (s) at holding
valve
– JLG Sizzor –
REMEDY
Activate Emergency stop switch
Release joystick, then select function
Re-connect cable to platform box and check
wiring at base
Check voltage with VOM. Unplug battery
charger
Check voltage with VOM. Plug in battery
charger
Check wire terminations on line contactor
and harness connection at base. Tighten
connections as necessary
Clean corrosion from line contactor
Replace line contactor
Repair or replace wiring as necessary
Replace the line contactor
Determine cause. Repair or replace motor as
necessary
Replace motor
Use VOM to verify limit switch inputs. Adjust
or repair malfunctioing limit switch
Use VOM to verify limit switch inputs. Adjust
or repair malfunctioing limit switch
Lower platform below drive cutout height
Repair wiring on lift cylinder (s) at holding
valve